Mounting:
1.
Using the dimensions below, mark the mounting and wire
hole locations onto the proposed mounting surface. Drill two,
.250" diameter mounting holes and a 1.75" (minimum) wire
access hole into the mounting surface.
2.
Feed the M9V wires through the wire access hole in the
mounting surface. Insert the molded grommet into their
respective mounting holes. With the assembly in position and
using the hardware provided, tighten the mounting screws
until the lighthead assembly is drawn firmly against the
mounting surface. A torque value of 12 in-lb. (max.) is
typically required to achieve this. DO NOT OVER TIGHTEN!
3.
Using appropriately sized wires (minimum 18 AWG), extend
the M9V wires to their designated connections. Refer to the
diagram shown for wiring and fusing information.
Wiring & Operation:
Important! Waterproof butt splices and/or connectors are
required if that connection could be exposed to moisture. Any
unused wires must be sealed (waterproofed) to prevent
moisture infiltration.
RED - Warning Light:
Apply +VBAT to the RED wire to activate
the Warning light.
WHT/VIO - ScanLock™ Pattern Selection:
This feature allows
the user to select from several available flash patterns. Lighthead
must be switched on for Scan-Lock to work.
WHT/BLK - Perimeter Light:
Apply +VBAT to activate the
Perimeter light.
VIOLET - Low Power:
The type of switch used depends on how
the operator wishes Low Power to function:
Latching Mode:
By apVBAT to the VIO wire for less
than 1 sec., the lighthead is “latched” into low power. The unit
must be turned off and then back on to restore normal
operation. For this mode, a momentary switch is preferred.
Level Mode:
ApVBAT to the VIO wire for more than 1
sec. holds the lighthead in low power mode until voltage is
removed. For this mode, a toggle switch is preferred.
TO CYCLE THROUGH ALL PATTERNS:
Apply +VBAT to the
WHT/ VIO wire for less than 1 second and release. To cycle
backward through patterns apply +VBAT to the WHT/VIO wire for
over 1 second and release.
TO SET A PATTERN AS DEFAULT:
Allow the pattern to run for
more than 5 seconds. The lighthead will now display this pattern
when active.
TO RESET TO THE FACTORY DEFAULT PATTERN:
Turn off
power. While apVBAT to the WHT/VIO wire, turn power on.
The lighthead will reset to its default pattern.
GREY - SYNC:
To SYNC 2 lightheads, configure both lightheads to display the
same Phase 1 (Simultaneous) pattern. Turn power off and connect the GREY
wire from each lighthead together. Activate the lightheads and their patterns will
be synchronized. To configure 2 lightheads to alternate their patterns, advance
either lighthead to Phase 2 (Alternating) of the current pattern. Cut and insulate
this wire if not used.
BLACK (12V) or BLK/WHT (24V) - Ground:
Connect this wire to Chassis
Ground.
CAUTION! DO NOT LOOK DIRECTLY AT THESE LEDS WHILE THEY ARE ON.
MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!
IMPORTANT WARNING!
.250 (2 places)
9.06
1.750
1.00
MOUNTING DIMENSIONS
WIRING DIAGRAM
M
O
U
N
T
I
N
G
S
U
R
F
A
C
E
Flange
Molded
Grommet
M9V
Lighthead
#8 x 1.75”
PPHSMS
BLK/WHT (24V Models)
GRY (SYNC)
WHT/VIO
RED
VIO
WHT/BLK
SP/ST
SP/ST
SP/ST
Mom. SW
To +VBAT
To +VBAT
To +VBAT
To +VBAT
To Ground
3A Fuse
1A Fuse
1A Fuse
3A Fuse
M9V
Lighthead
BLK (12V Models)
SignalAlert™ PH1
SignalAlert PH2
ComAlert™ 75 PH1
ComAlert 75 PH2
Comet Flash® PH1
Comet Flash PH2
LongBurst™ PH1
LongBurst PH2
PingPong™ 75 PH1
PingPong 75 PH2
SingleFlash 75 PH1
SingleFlash 75 PH2
DoubleFlash 75 PH1
DoubleFlash 75 PH2
TripleFlash™ 75 PH1
TripleFlash 75 PH2
Bold = SYNC Pattern
PH1 = Phase 1 PH2 = Phase 2
#
#
Name
Name
Cert.
Cert.
SingleFlash 60
SingleFlash 90
SingleFlash 120
SingleFlash 240
DoubleFlash 120
Tripleflash 120
ComAlert™ 150
PingPong™ 120
ActionFlash™ 60
ActionFlash 120
Action SF 60/120
Action SF120/TF75
ModuFlash
CalScan
ActionScan
STEADY
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2, 4
1,2,3,4
1,2,3,4
1, 3,4
1,2,3,4
1,2,3,4
1, 3,4
1,2,3,4
1,2, 4
1,2,3,4
1,2, 4
1,2,3,4
1,2,3,4
1, 3,4
Note: Each pattern is certified compliant in up to 4 classifications, shown in
the “Cert” column:
1. SAE
2. CA Title XIII
3. NFPA
4. KKK
Pattern List: