Page 2

Mounting:

1.

Using  the  dimensions  below,  mark  the  mounting  and  wire
hole locations onto the proposed  mounting surface. Drill two,
.250"  diameter  mounting  holes  and  a  1.75"  (minimum)  wire
access hole into the mounting surface.

2.

Feed  the  M9V  wires  through  the  wire  access  hole  in  the
mounting  surface.  Insert  the  molded  grommet  into  their
respective mounting holes. With the assembly in position and
using  the  hardware  provided,  tighten  the  mounting  screws
until  the  lighthead  assembly  is  drawn  firmly  against  the
mounting  surface.  A  torque  value  of  12  in-lb.  (max.)  is
typically required to achieve this. DO NOT OVER TIGHTEN!

3.

Using appropriately sized wires (minimum 18 AWG), extend
the M9V wires to their designated connections. Refer to the
diagram shown for wiring and fusing information.

Wiring & Operation:

Important!  Waterproof  butt  splices  and/or  connectors  are
required if that connection could be exposed to moisture. Any
unused  wires  must  be  sealed  (waterproofed)  to  prevent
moisture infiltration.

RED - Warning Light: 

Apply +VBAT to the RED wire to activate

the Warning light.

WHT/VIO  -  ScanLock™  Pattern  Selection: 

This  feature  allows

the user to select from several available flash patterns. Lighthead
must be switched on for Scan-Lock to work.

WHT/BLK  -  Perimeter  Light: 

Apply  +VBAT  to  activate  the

Perimeter light.

VIOLET - Low Power: 

The type of switch used depends on how

the operator wishes Low Power to function:

Latching Mode: 

By apVBAT to the VIO wire for less

than 1 sec., the lighthead is “latched” into low power. The unit
must  be  turned  off  and  then  back  on  to  restore  normal
operation. For this mode, a momentary switch is preferred.

Level Mode: 

ApVBAT to the VIO wire for more than 1

sec.  holds  the  lighthead  in  low  power  mode  until  voltage  is
removed. For this mode, a toggle switch is preferred.

TO  CYCLE  THROUGH  ALL  PATTERNS: 

Apply  +VBAT  to  the

WHT/  VIO  wire  for  less  than  1  second  and  release.  To  cycle
backward through patterns apply +VBAT to the WHT/VIO wire for
over 1 second and release.

TO  SET A  PATTERN AS  DEFAULT: 

Allow  the  pattern  to  run  for

more than 5 seconds. The lighthead will now display this pattern
when active.

TO  RESET  TO  THE  FACTORY  DEFAULT  PATTERN: 

Turn  off

power. While apVBAT to the WHT/VIO wire, turn power on.
The lighthead will reset to its default pattern.

GREY - SYNC: 

To SYNC 2 lightheads, configure both lightheads to display the

same Phase 1 (Simultaneous) pattern. Turn power off and connect the GREY
wire from each lighthead together. Activate the lightheads and their patterns will
be synchronized. To configure 2 lightheads to alternate their patterns, advance
either lighthead to Phase 2 (Alternating) of the current pattern. Cut and insulate
this wire if not used.

BLACK  (12V)  or  BLK/WHT  (24V)  -  Ground: 

Connect  this  wire  to  Chassis

Ground.

CAUTION! DO NOT LOOK DIRECTLY AT THESE LEDS WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

IMPORTANT WARNING!

.250 (2 places)

9.06

1.750

1.00

MOUNTING DIMENSIONS

WIRING DIAGRAM

M

O

U

N

T

I

N

G

S

U

R

F

A

C

E

Flange

Molded

Grommet

M9V

Lighthead

#8 x 1.75”

PPHSMS

BLK/WHT (24V Models)

GRY (SYNC)

WHT/VIO

RED

VIO

WHT/BLK

SP/ST

SP/ST

SP/ST

Mom. SW

To +VBAT

To +VBAT

To +VBAT

To +VBAT

To Ground

3A Fuse

1A Fuse

1A Fuse

3A Fuse

M9V

Lighthead

BLK (12V Models)

SignalAlert™ PH1
SignalAlert PH2
ComAlert™ 75 PH1
ComAlert 75 PH2
Comet Flash® PH1
Comet Flash PH2
LongBurst™ PH1
LongBurst PH2
PingPong™ 75 PH1
PingPong 75 PH2
SingleFlash 75 PH1
SingleFlash 75 PH2
DoubleFlash 75 PH1
DoubleFlash 75 PH2
TripleFlash™ 75 PH1
TripleFlash 75 PH2

Bold = SYNC Pattern
PH1  = Phase 1   PH2  = Phase 2

#

#

Name

Name

Cert.

Cert.

SingleFlash 60
SingleFlash 90
SingleFlash 120
SingleFlash 240
DoubleFlash 120
Tripleflash 120
ComAlert™ 150
PingPong™ 120
ActionFlash™ 60
ActionFlash 120
Action SF 60/120
Action SF120/TF75
ModuFlash
CalScan
ActionScan
STEADY

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.

17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.

1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4

1,2,   4
1,2,3,4
1,2,3,4
1,   3,4
1,2,3,4
1,2,3,4
1,   3,4
1,2,3,4
1,2,   4
1,2,3,4
1,2,   4
1,2,3,4

1,2,3,4
1,   3,4

Note:  Each pattern is certified compliant in up to 4 classifications, shown in

the “Cert” column:
1. SAE
2. CA Title XIII
3. NFPA
4. KKK

Pattern List:

Reviews: