background image

Page 2

4.

Connect  the  WHITE  and  the BLACK  8 AWG wires  onto  the  new
motherboard.

5.

Re-mount the Siren Amplifiers in their original location.

6.

Reconnect  the  Siren  Controller  and  Rotor  Controller  (3000/4000
systems-only).

7.

Mount  the  new  Battery  Charger  Panel  (if  applicable)  onto  the
cabinet. Route the new Battery Charger wires along the same path
as the old wires.

8.

Remove the Battery Disconnect Switch to gain access to the wire
from the Battery Charger. Remove and replace this wire with the
new wire provided. 

NOTE: Make sure the new Battery Charger

Wire is installed onto the “Battery” side of the switch!

PART I: REMOVAL OF EXISTING COMPONENTS

BEFORE BEGINING THIS PROCEDURE:

• DISCONNECT THE AC ELECTRICAL SUPPLY TO THE 

CABINET!

• ROTATE THE BATTERY DISCONNECT SWITCH TO THE “OFF” 

POSITION!

• DISCONNECT ALL BATTERY LEADS FROM THE BATTERY 

TERMINALS!

NOTE:

 This process involves removing multiple electrical connections.

Be  sure  to  tag  and  record  the  location,  color(s),  and  function  of  each
wire  or  harness  before  disconnecting.  Additionally,  take  note  of  the
paths  of  any  wiring  that  is  either  moved  or  removed  during  this
procedure

1.

Disconnect  all  electrical  connections  to  each  of  the  siren
amplifiers.

2.

Remove the siren amplifiers from the front panel.

3.

Disconnect the siren control harness from the siren controller. 

4.

Disconnect  any  connectors  between  the  Siren  controller  and  the
Rotor controller (3000/4000 systems-only).

5.

Remove the siren controller from the front panel.

6.

Disconnect  the  8  AWG  wire  harness  from  the  motherboard.

IMPORTANT! Be sure to insulate the WHITE wire!

7.

If a new Battery Charger Panel is to be installed, disconnect the
Battery  Charger  harness  and  remove  the  Battery  Charger  Panel
from the cabinet.

8.

Remove any additional wiring between the main cabinet and the
front panel.

9.

Unbolt and remove the front panel from the cabinet.

PART II: INSTALLATION OF NEW COMPONENTS

REFER  TO  THE  NEW  MANUAL(S)  INCLUDED  WITH  YOUR
EQUIPMENT  FOR  IMPORTANT  WIRING  INFORMATION  (Speaker,
Rotor, etc.).

1.

Remove the new front panel from its shipping crate.

2.

Disconnect  the  siren  amplifier  harness’  and  remove  amplifiers
from the panel.

3.

Mount the front panel onto the cabinet. 

IMPORTANT! Make sure

that all cabinet grounding straps are returned to their original
locations (under the front panel mounting hardware)!

9.

Reinstall  the  Battery  Disconnect  Switch  and  connect  the  Battery
Charger Harness to the System Harness.

10. Route the new External Status Light harness along the same path

as the previous Status Light harness.

11. Install the Battery Cables onto the appropriate Battery Terminals.

12. Restore  AC  power  to  the  cabinet  and  return  the  Battery

Disconnect Switch to the “ON” position.

Perform a complete test confirming proper operation of all station
functions before returning the station to active service!

Reviews: