13
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
Over-The-Top installation
(also available with one offset elbow)
Periscope installation
NOTE:
The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call
1-800-901-2042
, or visit us at
www.applianceaccessories.com.
In Canada, call
1-800-807-6777
or visit us at
www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP
0–5" Metal vent periscope
4396037RP
0"-18" Metal vent periscope
4396011RP
18" - 29" Metal vent periscope
4396014
29" - 50" Metal vent periscope
4392892
In-Wall metal DuraVent™ Periscope
4396028
Sure Connect™ venting kit
(over-the-top installation)
4396009RP
5' Universal connect vent, flexible dryer venting
4396010RP
6' SecureConnect™ vent, flexible dryer venting
4396013RB
Dryer vent installer’s kit
4396033RP
5' flexible dryer venting with clamps
4396727RP
8' flexible dryer venting with clamps
4396004
Dryer offset elbow
4396005
Wall offset elbow
4396006RW
DuraSafe™ close elbow
4396007RW
Through-the-wall vent cap
4396008RP
4" steel dryer venting clamps - 2 pack
8212662
Flush mounting louvered vent hood 4"
Special provisions for mobile home
installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
■
Select route that will provide straightest and most direct path
outdoors.
■
Plan installation to use fewest number of elbows and turns.
■
When using elbows or making turns, allow as much room
as possible.
■
Bend vent gradually to avoid kinking.
■
Use as few 90° turns as possible.
Determine vent length and elbows needed for
best drying performance:
■
Use following “Vent System Chart” to determine type of vent
material and hood combinations acceptable to use.
NOTE:
Do not use vent runs longer than those specified
in “Vent System Chart.” Exhaust systems longer than those
specified will:
■
Shorten life of dryer.
■
Reduce performance, resulting in longer drying times and
increased energy usage.
The “Vent System Chart” provides venting requirements that
will help achieve best drying performance.
NOTE:
Side and bottom exhaust installations for 27" wide
models have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m) 48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4 m) 38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
Vent System Chart
Summary of Contents for 27'
Page 2: ...2 Dryer Safety ...
Page 3: ...3 ...
Page 24: ...24 Sécurité de la sécheuse ...
Page 25: ...25 ...