background image

GB9

5. Grease filter alarm reset key

After 

80 hours

of operation, the ON key comes on to indicate that the grease filter needs cleaning.

Once the grease filter has been cleaned press "

5

" for at least 3 seconds while the hood is ON, and operating at any speed.

6. "6th Sense" key /"Air Quality Control" (Automatic Operation) 
IMPORTANT: this function does not activate if the hood is OFF.

With 

Automatic operation

the hood can operate in two different modes. To set either mode keep pressing key "

6

" until the desired mode is activated. The

"

6th Sense

" mode (key "

6

" comes on), ensures correct suction of cooking steams based on the environmental conditions detected.

During cooking the system promptly reacts to any Steam/Gas increase, and remains at the set speed for at least 1 minute before returning to the lower speed or
switching off.
At the end of cooking, when the environmental conditions have returned to those before cooking, the system switches off: However, if the conditions are similar
to the stand-by parameters, the hood will be switched off 30 minutes after, even if the stand-by parameters have not actually been reached.
The "

Air Quality Control

" mode ("

LD5

" comes on) uses the hood as an air monitoring system, ensuring a high air quality level.

The system promptly reacts to any Steam/Gas increase, and remains at the set speed for at least 1 minute before returning to the lower speed, or switching off.
After the effect of the gas is terminated, when the environmental conditions have returned to those before cooking, the system switches off:

Note: 

Each time the hood goes from OFF to Stand-by mode, the system enters "

6th Sense

" mode.

To exit 

Automatic Operation

press keys "

2

" or "

3

" (the "

LD5

" led or the "

6

" key go off), decreasing or increasing the automatic speed by one step, or press "

1

"

to return to 

Stand-By

mode.

7. Carbon filter alarm reset key 

After 

320 hours

of operation, with the hood ON, the carbon filter alarm reset key comes on to indicate that the carbon filter needs cleaning.

Once the carbon filter has been cleaned press "

7

" for at least 3 seconds while the hood is ON, operating at any speed, to reset the filter alarm.

In standard mode, the electronic system is set to provide notifications for the grease filter only.
To activate notifications for the carbon filter, place the hood in 

Stand-by

and then press keys "

5

" and "

7

" for 3 seconds.

Activation is confirmed by keys "

5

" and "

7

" flashing for 3 seconds.

Repeat the operation to deactivate carbon filter notifications. Key "

5

" will flash for 3 seconds.

Each time the status is changed, an extended "beep" is heard.

Automatic sensor calibration

The system requires automatic sensor calibration. This calibration is performed, with the motor off, during first installation, as well as each time power supply is
cut off.
This operation is confirmed by key "

6

" flashing and key "

1

" coming on.

Manual sensor calibration

The system can also be manually forced to perform the calibration procedure as follows:
Place the hood in Stand-by and press "

6

" for 5 seconds.

This operation is confirmed by key "

6

" flashing and key "

1

" coming on.

This operation should be performed when:

the hood is installed for the first time;

there is a power cut lasting several hours or days;

a very quick temperature change occurs in the kitchen.

Sensor test

The sensor test is performed continually during automatic operation.
In case of fault, keys "

1

" and "

6

" flash (contact customer service). In this case it will still be possible to use the hood in manual mode.

Note:

to optimise sensor performance:

always keep the sensor area clean and free from any obstructions that may prevent air from reaching the sensor element;

ensure that no water (or other liquid) sprays reach the sensor;

avoid contact of the sensor with organic solvents, silicon resins and ammonia.

Summary of Contents for 891

Page 1: ...maintenance operations must be carried out by a qualified technician When drilling through the wall pay attention not to damage electric connections and or pipes Air vents must always discharge to the outside The manufacturer rejects all responsibilities for any damage caused by improper use or wrong settings Appropriate maintenance and cleaning ensure the good working order and the best performan...

Page 2: ... in an accessible place install a standardised double pole power switch that will enable complete isolation from the mains in case of category III overvoltage conditions in accordance with installation rules GENERAL RECOMMENDATIONS Before use Remove cardboard protection pieces protective film and adhesive labels from accessories Check the appliance for any transport damage During use To avoid any ...

Page 3: ...service number number after the word Service on the rating plate located on the inside of the appliance The service number is also indicated on the guarantee booklet your full address your telephone number If any repairs are required please contact an authorised After sales Service to guarantee that original spare parts will be used and repairs carried out correctly Never use steam cleaning equipm...

Page 4: ...dicated by the three points and with a gentle pressure lift the cover from its position 3 Remove the faulty light bulb and replace with a new one 4 Replace the cover spring lock ACTIVE CARBON FILTER filter models only The carbon filter must be washed once a month in the dishwasher at the highest possible temperature using a standard dishwasher detergent It is recommended that nothing else is place...

Page 5: ...od steam outlet and the discharge duct fits correctly to both IMPORTANT If already installed remove the carbon filter s Filtering model The air is filtered through one of the carbon filters and then resent to the room IMPORTANT Ensure appropriate air circulation around the hood Before using the hood ensure that the carbon filter s has have been installed The hood should be installed away from part...

Page 6: ...the hood to the wall in its final position with the 2 screws 15 Connect the cooking steam discharge tube to the fitting B The tube must be directed towards the outside suction model or towards the deflector filter model The deflector F must be fitted to the G chimney support bracket using 2 screws 16 Connect the power supply 17 Fit the chimneys in position above the hood and fully cover the suctio...

Page 7: ...GB7 ...

Page 8: ...st 2 seconds to switch the hood OFF and disable all keys with the exception of key 4 2 Speed decrease key 3 Speed increase key The speed of the motor may be increased or decreased from speed one up to intensive speed and vice versa by pressing keys 2 and 3 respectively Press and hold down keys 2 or 3 to keep increasing decreasing the speed at one second intervals The current speed is shown by the ...

Page 9: ... return to Stand By mode 7 Carbon filter alarm reset key After 320 hours of operation with the hood ON the carbon filter alarm reset key comes on to indicate that the carbon filter needs cleaning Once the carbon filter has been cleaned press 7 for at least 3 seconds while the hood is ON operating at any speed to reset the filter alarm In standard mode the electronic system is set to provide notifi...

Page 10: ... selection will be confirmed by the selection itself flashing 3 times Once the selection has been saved the hood will go off Note The type of hob set by default is the Gas hob Disconnect the appliance from the power supply Cleaning the perimeter suction panel Dismantling Pull the panel FRONT SIDE downwards Cleaning The suction panel must be cleaned with the same frequency as the grease filter Use ...