background image

Summary of Contents for AC0052

Page 1: ...Care Operating Your Aw Conditioner Caring For Your Air Conditioner tf You Need Assistance Or Setvice Warranty 3 4 5 7 11 16 1 80 253 1301 Call with questions or comments AIR CONDITIONERS MODELS AC0052 ACQ062 ...

Page 2: ...l help alert you to such dangers as personal injury burns fire and electrical shock This symbol will help you avoid actions which could cause product damage scratches dents etc and damage to your personal property Our Consumer Assistance Center number l 800 253 1301 is toll free 24 hours a day If you ever have a question concerning your appliance s operation or if you need service first see If You...

Page 3: ...IS OR ANY OTHER APPLIANCE THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION I SAVE THESE INSTRUCTIONS Help us help you Please l Install the air conditioner in a window that will hold the weight and secure it in accordance with the Installation Instructions l Connect the air conditioner only to the proper kind of outlet with the correct electrical supply and grounding See the Installation Instruc tio...

Page 4: ... illustrations of your appliance Use them to become familiar with where all parts and features are located and what they look like Model anb serial number label Cohrol panel Rem able door front panel Air direction louvers and tab Slide out air filter ...

Page 5: ... Control to CLOSED for maxi mum cooling performance 2 Set Fan Control to the desired setting QUIET COOL _ for sleeping comfort REGULAR COOL for normal cooling MAX COOL for maximum cooling FAN ONLY for circulating room air when no cooling is desired 3 Turn the Thermostat Control to the desired setting You can adjust the air conditioner s cooling performance by turning the Thermo stat Control clockw...

Page 6: ...t Exhaust Control to CLOSED 2 Set Fan Control to desired setting If no cooling is desired set Fan Control to FAN ONLY EXHAUST VENT 3 Set Thermostat Control to desired setting OPEN CLOSED NOTE For maximum performance the Exhaust Vent Control must be in the CLOSED position when cooling or room air circulation is desired Changing air direction The louvers in the top grille area of the air conditioner...

Page 7: ... solvents abrasive cleaners or strong detergents Fire or product damage could result Cleaning the front panel 1 2 3 4 5 6 7 8 9 10 Unplug the power cord Remove the front panel from unit for cleaning Press down at top of front panel to release it from the top of the cabinet Pull top of front panel toward you Lift front panel up and away from the bottom spring clips Remove the slide out air filter a...

Page 8: ...ng Expense of annual inspection is the customer s responsibility OR If you are familiar with electrical appliances you can do the cleaning and maintenance yourself If you choose to do so follow these steps Electrical Shock Product Damage and Personal Injury Hazard l Unplug power cord from receptacle before performing any maintenance Be sure no liquid gets into the motor electrical control box or c...

Page 9: ... other liquids get inside Water or other liquids could damage the insulation and cause serious mechanical problems 9 Clean and hose out the base coils and condensate pans Clean air conditioner at least once a year or more often if the condenser coils and pans collect dirt sand leaves insects or algae Also clean the air conditioner if you detect an odor coming from it 10 Remove plastic film from th...

Page 10: ...unting area Saving energy You can help save energy by following the tips below l Improve your home s insulation Seal all doors and windows Close the fireplace flue l Close all blinds and drapes on sunny sides of the house Add window awnings Keep the air filter clean l Do not block the airflow with drapes or furniture l Ventilate the attic High temperatures in the attic add to the air conditioner s...

Page 11: ...et to OFF Set the Fan Control to a setting other than OFF The Thermostat Control is not set correctly Set the Thermostat Control to a setting cooler than the room temperature A household fuse has blown or a circuit breaker has tripped Replace fuse or reset circuit breaker The local power has failed Wait for power to be restored Unit blows A time delay fuse is not being Replace fuse with a time del...

Page 12: ...ING MACHINES 6 MAJOR SERVlCE k REPAIR DRVEFIS SERVICE k REPAIR Sea Whlflpool AppWsncea OT Sea WhIrlpool Applhoea or Atihorlzed Whirlpool Servlca Aulhorked WhIrlpod Service Emmpbrxvz seNix Co Ex mpk3rxYZ service Co 4 If you need FSP replace ment parts FSP is a registered trademark of Whirlpool Corporation for quality parts Look for this symbol of quality whenever you need a replacement part for you...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...of the air conditioner if it is installed in an overhead or other inaccessible location or not installed in accordance with published installation instructions E Repairs to parts or systems caused by unauthorized modifications made to the appliance Service under the full warranties must be provided by an authorized WhirlpoolSM service company WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTA...

Reviews: