Table of burner and nozzle specifications
Table 1- HU G30 (GPB-B)
G20 G2.350 (GZ35)
Burner
Diameter
(mm)
Thermal
power
kW
(p.c.s.*)
Thermal
power
kW
(p.c.s.*)
By-pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal
power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
Thermal
power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
Reduc.
Nominal
(mm)
(mm)
Nominal
(mm)
Nominal
(mm)
Fast (Large)(R)
100
0,80
3,00
41
87 218 3,40
128 324 58
397
Semi Fast
(Medium) (S)
75
0,50 1,90
30 69 138 2,10
104 200 1,9 143 X 251
Auxiliary (Small)
(A)
51
0,50
1,00 30 50 73 1,15 78 109 32
Supply
Pressures
Minimum (mbar)
Nominal (mbar)
Maximum (mbar)
25
20
30
10
( )
* A 15°C e 1013 mbar-dry gas
G20 (GZ50) p.c.s. 37,78 MJ/m
G30 (GPB-B) p.c.s. 49,47 MJ/Kg
THERMOSTAT indicator light
When this is illuminated, the oven is generating heat.
It switches off when the inside of the oven reaches
the selected temperature. At this point the light
illuminates and switches off alternately, indicating
that the thermostat is working and is maintaining the
temperature at a constant level.
Oven light
This is switched on by turning the SELECTOR knob to
any position other than “0”. It remains lit as long as the
oven is operating. By selecting
with the knob, the
light is switched on without any of the heating elements
being activated.