4-23
12. Measure the new evaporator inlet and
outlet tubes, and cut the existing lines to
the proper lengths.
13. Remove the ten mounting screws (five
on each side) from the evaporator.
8. Remove the seven screws (three on
each side and one on top) from the lou-
ver housing assembly, and lift the assem-
bly off the top of the unit so that you can
access the fan.
Top Screw
3 of 6
Screws
Louver Housing
Assembly
9. Cut the wire tie and pull the de-ice therm-
istor out of the housing in the evaporator.
10. Remove the wire ties and foam insula-
tion from around the evaporator inlet and
outlet tubing.
11. Braze on an access valve and discharge
the sealed system refrigerant into an ap-
proved refrigerant recovery system.
Inlet & Outlet
Tubing Insulation
14. Lift the evaporator out of the unit.
REASSEMBLY NOTE:
Be sure to replace the
wire ties that you removed with new ties, and
secure the wires neatly together.
5 Evaporator
Screws
De-Ice
Thermistor
Summary of Contents for ACP102PR
Page 4: ... iv NOTES ...
Page 10: ...1 6 NOTES ...
Page 26: ...3 12 NOTES ...
Page 60: ...6 2 NOTES ...
Page 61: ...6 3 NOTES ...
Page 62: ...6 4 NOTES ...
Page 64: ......