E L E C T R I C A L R E Q U I R E M E N T S
ELECTRICAL REQUIREMENTS
PLUG TYPE
6
7
3-prong
ground-
type outlet
Ground
prong
Power supply cord
3-prong
ground-
type outlet
115-volt models with amperes
up through 7.5
For 115-volt models with amperes
from 7.6 to 12.0
SEE PAGE
3-prong
ground plug
3-prong
ground plug
Ground
prong
Power supply cord
115-volt models with amperes up
through 7.5
Outlet wiring
Outlet wiring should be a minimum of
14 gauge. Use copper wire only. It is the
responsibility of the consumer to provide
proper and adequate receptacle wiring,
installed by a qualified electrician. Observe
National Electrical Code and all local
governing codes and ordinances.
Electrical connection
Electrical ground is required on this air
conditioner.
Recommended ground method
For your personal safety, this air conditioner
must be grounded. This air conditioner is
equipped with a power supply cord
having a 3-prong ground plug. To minimize
possible shock hazard, the cord must be
plugged into a mating 3-prong ground-type
outlet, grounded in accordance with the
National Electrical Code (ANSI/NFPA 70 –
latest edition) and local codes and
ordinances. If a mating outlet is not
available, it is the responsibility of the
customer to have a properly grounded
3-prong outlet installed by a qualified
electrician.
Electrical requirements
A 115-volt (103.5 min., 126.5 max.), 60-Hz,
AC-only, 15-ampere fused electrical supply
is required (time delay fuse or time delay
circuit breaker required). It is required that a
separate circuit, serving only this air
conditioner, be provided.
3-prong
ground
plug
Power
supply
cord
Ground
prong
3-prong
ground-type
outlet
(double outlet)