background image

4 - INSTALLATION INSTRUCTIONS

0813_GB_42

- GAS KITCHENS WITH PILOT

04/2008

4.1 Safety rules

• Only a local gas utility technician is authorized to carry out gas

installations and connections. The statutory regulations (applied
in Germany VDE, Austria ÖVE, Switzerland SEV, etc.) and connec-
tion conditions performed by the gas utility must be strictly
observed.

•  In compliance with international regulations, when connecting

the appliance to the mains power supply, a device with a mini-
mum aperture of 3 mm between contacts must be fitted
upstream of the appliance, allowing omnipolar disconnection of
the appliance from the mains. Also, a high-sensitivity automatic
differential switch must be installed which protects against direct
or indirect contact with live electrical parts and against current
leakage (maximum current leakage permissible by regulations is
1 mA/kW).

• Connection to a power balance system for the installation in a all

is given through a connection point. Follow the VDE 0100 T 410
connection rules or local rules.

•  Compare technical datas on grey stickers to those written on this

manual and present power supply.

•  Do not bend, crush or damage the cables against sharp corners.

•  Lay the cables so as to avoid contact with extremely hot surfaces.

• Connection to the grid must be carried out with at least a cable

type NYM or H07RN-F.

•  The cable - which is totally sheathed – must be led inside the

appliance through the cable clamp and cable raceway installed
on the appliance.

•  Ventilation system installation can be carried out only by expert

personnel.

•  If the appliance is to be installed near walls, dividing walls, kit-

chen equipment or decorative panelling, these should be in non-
inflammable material. If not, all appliances must be coated with
thermal-insulation fireproof material. Make sure that all fire pre-
vention standards and safety precautions are strictly adhered to.

4.2 Structure, equipment and safety devices
of the unit 

Robust steel frame, with 4 height adjustable feet. 

Steel outer panelling.

4.2.1 Cooking zone 

•  Burner with stabilized flame.

• Pilot 

flame.

•  Gas cocks with safety and adjustable from maximum to minimum.

•  Thermoelectric ignition safety.

Enamelled cast-iron pan supports.

•  The bodies of the burners, the injector-holder cups and the flame

spreaders are made of nickelled cast-iron.

•  18/10 chrome-nickel steel cooking top.

•  Knobs in thermosetting material.

4.2.2 Oven

The cooking chamber is made of stainless steel. 

The runners for the pans are made of chromium-plated steel.

Extractable chromium-plated steel grill.

The door, with double wall and thermal insulation, is equipped with
an insulated handle and a hinge with balanced spring.

The insulation of the cooking chamber is rockwool.

Gas version GN 1/1

The tubular burners are in stainless steel and are resistant to ther-
mal and mechanical stress. Temperature adjustment between 100°C
and 300°C, is made with the thermostat.

4.3 Assembly

4.3.1 Installation premises

The appliance must be installed in a well-ventilated room, and if
possible under a range hood (check current regulations).

The appliance can be installed on its own or with other similar
equipment.

If the appliance is to be installed near inflammable walls, a minimum
distance of 150 mm around the sides and back should be allowed. 

If this distance cannot be obtained, take proper heat-protection
action such as fitting tiles or thermal radiation protection material
to the walls.  

Before connecting the appliance to the gas supply, check on the
data plate that the appliance is suitable and type-tested for the
type of gas available. 

If the type of gas indicated on the data plate of the appliance does
not correspond to the gas which is present, refer to the paragraph
5.1.10 “Conversion and adaptation”. 

4.3.2 Statutory regulations and technical requirements

During installation of the appliance, the following regulations must
be adhered to:

•  Relevant legal directives;

•  Local building and combustion regulations;

•  "Technical rules for gas systems" worksheet;

•  "Technical rules for liquid gas" worksheet;

•  “Gas installations in industrial kitchens” worksheet;

•  Relative accident prevention standards;

•  Local gas utility regulations;

•  Local building and fire codes.

4.3.3 Installation

Before installation, gas connection, power check, conversion or
adjustment and start up ask for gas supply company advice.

4.3.4 Gas connection

For the gas connection a straight 3/4" connector is provided, com-
plete with seal, to be fitted at the mouth of the apparatus gas train.
The connection to the mains can be fixed or detachable by inserting
a suitable type-tested tap.  

If hoses are used, they must be in stainless steel and in compliance
with the DIN 3383, part 1 or DIN 3384 regulations. 

After completing gas connection, check for leaks using a special
leak-detector spray.

4.3.5 Smoke extraction

These kitchens are type A appliances, thus no smoke extraction sys-
tem is required.

For the ventilation of the room where the appliance is installed,
refer to related legislation.

7

· 16

Summary of Contents for ADN 612

Page 1: ...0813_GB_42 Instructions for installation use e maintenance GAS KITCHENS WITH PILOT ADN 612 ADN 613 04 2008 ...

Page 2: ...0813_GB_42 GAS KITCHENS WITH PILOT 2 16 04 2008 CHARACTERISTICS Supplied by Date Customer Service FAX e mail ...

Page 3: ...injectors 8 5 1 12 Replacement of pilot injectors of open flames 8 5 1 13 Setting reduced capacity power 9 5 1 14 Replacement of burner injector of gas oven GN 1 1 9 5 1 15 Setting reduced capacity power oven 9 5 2 Maintenance 9 5 3 Replacing parts 10 5 3 1 Open flame gas cock 10 5 3 2 Open flame thermocouple 10 5 3 3 Gas cock gas oven GN 1 1 10 5 3 4 Plug gas oven GN 1 1 10 5 3 5 Thermocouple gas...

Page 4: ...ENS WITH PILOT 4 16 04 2008 ADN 612 ADN 613 800 34 700 496 25 55 545 150 60 678 700 34 45 710 800 910 45 34 1000 1000 700 34 45 45 0 0 0 0 0 0 0 0 0 0 0 0 Data plate Gas 1 2 Gas 1 2 Data plate Data plate Gas 1 2 1 DIAGRAM ...

Page 5: ...000 x 700 x 900 800 x 700 x 900 1000 x 700 x 900 N 51BS3547 51BS3547 51BS3547 51BS3547 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 20 II2H3 P mbar 30 37 20 II2H3 P mbar 28 37 20 25 II2L3B P P mbar 30 30 II2ELL3B P P mbar 50 50 20 20 II2E 3 P mbar 28 37 20 25 II2H3B P P mbar 50 50 20 I2E P mbar 20 II2H3B P P mbar 30 30 II2H3 P mbar 28 37 20 I3B P P mbar 30 30 I3 P mbar 28 3...

Page 6: ...20 G30 G31 HuB 9 45 kWh m3 in m3 h HuB 12 87 kWh kg in kg h Nominal thermal power Minimal thermal capacity Nominal thermal power Minimal thermal capacity G20 G30 G31 20 mbar 28 37 mbar kW kW kW kW II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 7 Open B Ø 100 8 4 0 1 2 C Ø 120 12 6 0 1 8 0 423 0 313 145 Adjustable 100 45 27 19 9 Open 0 635 0 470 185 Adjustable 125 75 27 19 Hour consumpti...

Page 7: ...e cooking chamber is made of stainless steel The runners for the pans are made of chromium plated steel Extractable chromium plated steel grill The door with double wall and thermal insulation is equipped with an insulated handle and a hinge with balanced spring The insulation of the cooking chamber is rockwool Gas version GN 1 1 The tubular burners are in stainless steel and are resistant to ther...

Page 8: ...he appliance or on the table 1 5 1 6 Operation control Start the appliance in accordance with the instructions Check that the appliance does not have any leaks by using a leak detecting spray Check ignition and that flame on the main burner lights pro perly and is correctly formed even on low A servicing and maintenance contract is recommended 5 1 7 Check of pilot flame For proper regulation the p...

Page 9: ...type of gas see table 1 install in reverse order After the replacement check the seal using a leack detector spray 5 1 15 Setting reduced capacity power oven Loosen screw pos 9 fig 2 by two or three turns after having remo ved the knob and the control panel cover Light the burner and keep it lit for at least 10 minutes with the knob in the position then put the knob to and tighten screw pos 9 fig ...

Page 10: ...ocouple Loosen the nut pos 8 fig 1 for fastening the thermocouple on the valve and on the burner pos 17 fig 1 and replace the piece pos 14 fig 1 install in reverse order 5 3 3 Gas cock gas oven GN 1 1 Loosen the fittings pos 10 and 11 fig 2 which are for the connec tion for the gas pipe and the thermocouple unscrew the screws pos 12 fig 2 remove the coil of the thermostat from its place in the coo...

Page 11: ...x and min supply position of easily selectable intermediate levels To shut off the burner turn the knob to the right to position the main burner will go out To shut off the pilot light place the knob in position 0 6 3 Lighting and shutdown of gas oven GN 1 1 Press and turn it to the left until position 7 the knob pos 14 fig 2 Hold the knob down and at the same time press the piezo ignition button ...

Page 12: ...t clean and in contact with air at all times When not running keep appliance doors open so as to allow air to run through it Regularly remove calcium grease starch and egg white deposits where rust may build up if there is lack of air Do not use bleach ing products or products containing chloride Follow all indica tions given by the company concerning special soaps and clean ing methods to be used...

Page 13: ...quipment collection centre or returned to the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste Suitable separated collection so that the unit no longer used can...

Page 14: ...0813_GB_42 GAS KITCHENS WITH PILOT 04 2008 14 16 NOTES ...

Page 15: ...0813_GB_42 GAS KITCHENS WITH PILOT 04 2008 15 16 NOTES ...

Page 16: ... PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: