background image

WARNING

It is not possible to adjust nominal capacity in advan-
ce. 

Checking power rating when using LP
gas

Check that the type of nozzles used match manufactu-
rer's specifications. 
Check that the output pressure regulator installed colla-
terally to the plant conforms to the specifications laid
down in paragraph "Checking input pressure" page 8
(see data plate or measure the pressure). 

Checking the pilot light

When correctly adjusted, the pilot light flame will com-
pletely surround the thermocouple and will not flicker; if it
does, turn the pilot adjusting screw (30 - Fig. 1 - page
11).

Checking the primary air 

The devices are provided with adjustment of the primary air.
Depending on the type of gas, position the washer at mea-
surement “A” (Fig. 1) indicated in table 1. 

Checking the functions 

- Start the appliance in accordance with the 

instructions; 

- Check the gas tubes for leaks;
- Check that the flame on the main burner lights 

properly and is correctly formed; 

- Check that the pilot light is correctly regulated; 
- Draw up a servicing and maintenance contract. 

Note for the installer 

- Explain and demonstrate to the user how the machine

works according to the instructions and hand him this
manual. 

- Remind the user that any structural alterations to the

room housing the appliance may affect the combu-
stion air supply. Once the alterations have been com-
pleted, the appliance and its functions should be tho-
roughly checked. 

Running the appliance on other types
of gas 

When changing to another type of gas, e.g. from natural
to LP, or to another gas group, consult the “TECHNICAL
DATA” table to determine the correct nozzles to use. 
The nozzles for the main burners for different types of
gas, marked in 100ths of mm, are in a case supplied with
the appliance. 
When the appliance has been transformed or adapted,
r e c h e c k   i t s   f u n c t i o n s   a s   d e s c r i b e d   i n   p a r a g r a p h
"Checking the functions" page 10. 

Replacing the main burner nozzle 
(Fig. 1) 

To change the nozzle (28), remove the air adjustment (27)
loosening the screw (33), unscrew it from the nozzle hol-
der using a 12 mm wrench and replace with a new one
(see “TECHNICAL DATA” table). 
After fitting the nozzle, reset primary air distance “A”
(see “TECHNICAL DATA” table). 

Adjusting the pilot burner (Fig. 1) 

The pilot burner is readily accessible when the door is
opened. 
Unscrew nut (34) and using a screwdriver adjust the by-
pass. For use with LPG, the adjusting screw must be ful-
ly screwed down. Tighten the nut, making sure the ga-
sket has been inserted.

MAINTENANCE

Attention!

Before carrying out any maintenance or repair work,
disconnect the appliance from the mains.

The following maintenance programme should be car-
ried out at least once a year: 
- Check that all the safety and setting devices are

working properly; 

- Check that the burners are working properly with re-

gard to: 

- ignition 
- combustion safety;
- Check the functions of the appliance as described in

paragraph "Checking the functions", page 10; 

- Check the gas venting path (make sure the gas is cor-

rectly evacuated). 

041-03 - Gas fryers

10

1

2

19

2

Summary of Contents for AGB 432/WP

Page 1: ...041_03 Installation operating and maintenance instructions 11 2005 GAS FRYERS AGB 519 WP AGB 520 WP AGB 432 WP AGB 436 WP AGB 434 WP AGB 438 WP AGB 440 WP AGB 442 WP AGB 444 WP AGB 446 WP ...

Page 2: ...hecking the primary air 10 Checking the functions 10 Note for the installer page 10 Running the appliance on other types of gas 10 Replacing the main burner nozzle 10 Replacing the pilot burner nozzle 10 Maintenance 10 Replacing parts 11 Gas valve 11 Safety thermostat 11 Burner 11 Thermocouple 11 Ignition plung 11 Electrical components 11 Using the appliance 12 Preparation for use 12 Filling the t...

Page 3: ... 52 5 13 5 1 100 2 140 465 220 211 50 295 G 400 280 2 700 G TS 50 875 1896 52 5 52 5 13 5 1 100 2 140 465 220 50 695 G 800 280 2 700 G TS TS T S TS TS S T AGB 519 WP AGB 520 WP G TS T S 1 2 gas connector Safety thermostat Technical data Oil drain ...

Page 4: ... 21 100 2 140 465 210 215 60 290 TS G 400 310 2 900 G 310 2 900 G TS TS TS 800 875 1850 55 55 21 290 TS 100 2 140 465 210 60 G 50 T S S T AGB 432 WP AGB 434 WP AGB 436 WP AGB 438 WP G TS T S 3 4 gas connector Safety thermostat Technical data Oil drain ...

Page 5: ...fryers 5 Dimensions 400 310 2 900 G 310 2 900 G TS TS TS 800 530 TS 210 AGB 440 WP AGB 442 WP AGB 444 WP AGB 446 WP G TS T S 3 4 gas connector Safety thermostat Technical data Oil drain 210 215 60 TS 530 T T S S S ...

Page 6: ...51BQ2905 51BQ2905 51BQ2905 51BQ2905 2 CHARACTERISTICS OF THE APPLIANCES The instructions contained in this manual apply to our Gas deep fat fryer in the II2H3 category see table on page 7 The data plate is located on the front of the appliance and on the control panel It contains all necessary reference data such as the name of the manufacturer input pressure gas type setting etc 0051 TIPO TYPE CA...

Page 7: ... burner G20 G30 G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Reference Reference G20 G30 31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 2 2 0 952 0 655 2 x 160 2 x 110 Adjustable 20 2 2 1 904 1 310 4 x 160 4 x 110 Adjustable 2 x 20 2 2 1 270 0 873 2 x 185 2 x 125 Adjustable 20 2 2 2 540 1 746 4 x 185 4 x 125 Adjustable 2 x 20 AGB 519 WP AGB 432 WP AGB 440 WP A 25...

Page 8: ...equisites During assembly the following legal and technical re quisites should be adhered to relevant national legislation local building and fire safety regulations worksheet Technical rules for installing gas worksheet Technical rules for LP gas worksheet Gas installations in industrial kitchens industrial injury legislation local Gas Board regulations current CEI regulations INSTALLATION Assemb...

Page 9: ...ssure tolerances to ob tain the nominal power according to the agreed nozzles from 15 to 22 5 mbar for gases of the second family from 25 to 45 mbar for gases of the third family propane The appliance will not work outside the above pressure thresholds If you wish to check the nominal capacity further you may do so using a gas meter according to the so called volumetric method As a rule however it...

Page 10: ...ghly checked Running the appliance on other types of gas When changing to another type of gas e g from natural to LP or to another gas group consult the TECHNICAL DATA table to determine the correct nozzles to use The nozzles for the main burners for different types of gas marked in 100ths of mm are in a case supplied with the appliance When the appliance has been transformed or adapted recheck it...

Page 11: ... insert the new part Burner Fig 1 Unscrew nozzle 28 and nut 29 Loosen the screws 26 fixing the burner to the chamber Replace the burner Thermocouple 38 Fig 1 Unscrew the nipple fixing the thermocouple to the valve loosen the 2 screws 25 on the pilot burner and replace the thermocouple To simplify the operation and all those concerning the pilot burner screws 31 may be removed and the pilot burner ...

Page 12: ...d above all the tank see paragraph Cleaning and maintenance Filling the tank Check that the oil drainage outlet is closed Fill the tank up to the maximum level mark with frying oil or liquid fat Turning on and off Fig 3 Turn on gas supply Lighting the pilot burner Press the button 14 and as the same time the piezoelec tric lighter 12 to light the pilot flame which can be seen through hole 10 after...

Page 13: ...OF MAINTENANCE Warning Never clean the appliance with jets of water whether direct or pressurised Allow the machine to cool down before cleaning Giving the appliance a thorough clean every day after tur ning it off will keep it in perfect working order and make it last longer All steel parts should be cleaned with water and a deter gent using a damp cloth do not use abrasive substances or corrodin...

Page 14: ...PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...