WARNING
It is not possible to adjust nominal capacity in advan-
ce.
Checking power rating when using LP
gas
Check that the type of nozzles used match manufactu-
rer's specifications.
Check that the output pressure regulator installed colla-
terally to the plant conforms to the specifications laid
down in paragraph "Checking input pressure" page 8
(see data plate or measure the pressure).
Checking the pilot light
When correctly adjusted, the pilot light flame will com-
pletely surround the thermocouple and will not flicker; if it
does, turn the pilot adjusting screw (30 - Fig. 1 - page
11).
Checking the primary air
The devices are provided with adjustment of the primary air.
Depending on the type of gas, position the washer at mea-
surement “A” (Fig. 1) indicated in table 1.
Checking the functions
- Start the appliance in accordance with the
instructions;
- Check the gas tubes for leaks;
- Check that the flame on the main burner lights
properly and is correctly formed;
- Check that the pilot light is correctly regulated;
- Draw up a servicing and maintenance contract.
Note for the installer
- Explain and demonstrate to the user how the machine
works according to the instructions and hand him this
manual.
- Remind the user that any structural alterations to the
room housing the appliance may affect the combu-
stion air supply. Once the alterations have been com-
pleted, the appliance and its functions should be tho-
roughly checked.
Running the appliance on other types
of gas
When changing to another type of gas, e.g. from natural
to LP, or to another gas group, consult the “TECHNICAL
DATA” table to determine the correct nozzles to use.
The nozzles for the main burners for different types of
gas, marked in 100ths of mm, are in a case supplied with
the appliance.
When the appliance has been transformed or adapted,
r e c h e c k i t s f u n c t i o n s a s d e s c r i b e d i n p a r a g r a p h
"Checking the functions" page 10.
Replacing the main burner nozzle
(Fig. 1)
To change the nozzle (28), remove the air adjustment (27)
loosening the screw (33), unscrew it from the nozzle hol-
der using a 12 mm wrench and replace with a new one
(see “TECHNICAL DATA” table).
After fitting the nozzle, reset primary air distance “A”
(see “TECHNICAL DATA” table).
Adjusting the pilot burner (Fig. 1)
The pilot burner is readily accessible when the door is
opened.
Unscrew nut (34) and using a screwdriver adjust the by-
pass. For use with LPG, the adjusting screw must be ful-
ly screwed down. Tighten the nut, making sure the ga-
sket has been inserted.
MAINTENANCE
Attention!
Before carrying out any maintenance or repair work,
disconnect the appliance from the mains.
The following maintenance programme should be car-
ried out at least once a year:
- Check that all the safety and setting devices are
working properly;
- Check that the burners are working properly with re-
gard to:
- ignition
- combustion safety;
- Check the functions of the appliance as described in
paragraph "Checking the functions", page 10;
- Check the gas venting path (make sure the gas is cor-
rectly evacuated).
041-03 - Gas fryers
10
1
2
19
2