INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
Check that all parts are included.
■
Literature Bag
■
Conversion orifice spuds (inside literature bag)
■
Anti-tip bracket must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply. See “Gas Supply Requirements” section.
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the oven frame behind
the left side of the broiler door.
■
The range should be located for convenient use in the
kitchen.
■
Recessed installations must provide complete enclosure of
the sides and rear of the range.
■
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
■
All openings in the wall or floor where range is to be installed
must be sealed.
■
Do not seal the range to the side cabinets.
■
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
■
The floor anti-tip bracket must be installed. To install the
anti-tip bracket shipped with the range, see “Install Anti-Tip
Bracket” section.
■
Proper gas supply connection must be available. See “Gas
Supply Requirements” section.
■
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
■
Use an insulated pad or 1/4" (0.64 cm) plywood under range
if installing range over carpeting.
IMPORTANT:
To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
Mobile home installations require:
■
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards
listed above.
■
Level
■
3/8" drive ratchet
■
Tape measure
■
Flat-blade screwdriver
■
Phillips screwdriver
■
Hand or electric drill
■
Slip-joint pliers
■
7 mm combination wrench
■
Pipe wrench
■
1/8" (3.2 mm) drill bit (for wood floors)
■
3/16" (4.8 mm) carbide-tipped masonry drill bit
(for concrete/ceramic floors)
■
Pipe joint compound resistant to LP gas
■
Non-corrosive leak-detection solution
B
A
C
A. Anti-tip bracket
B. Plastic anchors (2)
C. #10 x 1-1/2
”
screws (2)
4
Model/serial
rating plate
location