background image

GB4

Disposal of packing

The packing material is 100% recyclable and is marked with the recycle symbol 

. The various parts of the packing must therefore be disposed of responsibly

and in full compliance with local authority regulations governing waste disposal.

Scrapping the product

-

This appliance is marked in compliance with European Directive 2012/19/EU, Waste Electrical and Electronic Equipment (WEEE).

-

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product.

-

The symbol 

on the product or on the accompanying documentation indicates that it should not be treated as domestic waste but must be taken to an

appropriate collection centre for the recycling of electrical and electronic equipment.

Scrapping of household appliances

This appliance is manufactured with recyclable or reusable materials. Dispose of it in accordance with local waste disposal regulations. Before scrapping, cut
off the power supply cable.

For further information on the treatment, recovery and recycling of household electrical appliances, contact your competent local authority, the collection
service for household waste or the store where you purchased the appliance.

SAFEGUARDING THE ENVIRONMENT

FILTERING OR DUCTING ?
!

Your cooker hood is ready to be used in suction version.

To use the hood in filtering version the special ACCESSORY KIT must be installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished or must be bought separately.

Note:

If furnished, in certain cases, the additional activated carbon filtering system may be installed on the hood.

Information about the conversion of the hood from suction version to filtering version is present in this manual.

Ducting version

In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connection ring located on top of the hood.

Attention! 

The exhausting pipe is not supplied and must be purchased apart.

Diameter of the exhausting pipe must be equal to that of the connection ring.

Attention!

If the hood is supplied with active charcoal filter, then it must be removed. 

Filter version

The aspirated air will be degreased and deodorised before being fed back into the room.
In order to use the hood in this version, you have to install a system of additional filtering based on activated charcoal.

GENERAL RECOMMENDATIONS

Before use

Remove cardboard protection pieces, protective film and adhesive labels from accessories. Check the appliance for any transport damage.
Use only the fixing screws supplied with the product for installation or, if not supplied, purchase the correct screws type. Use the correct length for the screws
which are identified in the Installation Guide.
In case of doubt, consult an authorised service assistance centre or similar qualified person.

The hood can look different to that illustrated in the drawings in this booklet. The instructions for use, maintenance and installation,
however, remain the same.

!

Do not carry out electrical or mechanical variations on the product or on the discharge conduits.

During use

To avoid any damage do not place any weights on the appliance. Do not expose the appliance to atmospheric agents.

Summary of Contents for AKR 551 JA

Page 1: ...User and maintenance manual GB ...

Page 2: ......

Page 3: ...isconnected from the power supply before carrying out any installation work Earthing of the appliance is compulsory Not necessary for class II hoods identified by the symbol on the specifications label The power supply cable must be long enough to permit connecting the appliance to the mains socket outlet Do not pull the power supply cable in order to unplug the appliance The electrical components...

Page 4: ...lace the filters Never flame cook food flambé under the appliance Using free flames might cause fire Do not leave frying pans unattended when frying as the frying oil may catch fire Failure to observe the instructions for cleaning the hood and replacing the filters may result in a fire The fume extractor hood must never be opened without the grease filters installed and it should be kept under con...

Page 5: ...is not fitted with a plug connect the wires according to the following table WARNING INSTALLATION Declaration of conformity This appliance has been designed manufactured and marketed in compliance with safety objectives of the LowVoltage Directive 2014 35 EU the ecodesign requirements of european regulations n 66 2014 n 327 2011 n 244 2009 n 245 2009 n 1194 2012 n 2015 1428 the protection requirem...

Page 6: ...KIT is furnished or must be bought separately Note If furnished in certain cases the additional activated carbon filtering system may be installed on the hood Information about the conversion of the hood from suction version to filtering version is present in this manual Ducting version In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connec...

Page 7: ... The service number is also indicated on the guarantee booklet Your full address Your telephone number If any repairs are required please contact an authorised After sales Service to guarantee that original spare parts will be used and repairs carried out correctly TROUBLESHOOTING GUIDE AFTER SALES SERVICE Never use steam cleaning equipment Disconnect the appliance from the power supply IMPORTANT ...

Page 8: ...er It absorbs unpleasant odours caused by cooking The saturation of the charcoal filter occurs after more or less prolonged use depending on the type of cooking and the regularity of cleaning of the grease filter In any case it is necessary to replace the cartridge at least every six mounths or when the filter saturation indication system if envisaged on the model in possession indicates this nece...

Page 9: ...2 Please check the plate in order to verify the total absorption and the light absorption Components not provided with the product Lamp Power W Socket Voltage V Dimension mm ILCOS D Code according IEC 61231 28 E14 230 67 Light Center Length HSGSB C UB 28 230 E14 67 Replacing lamps Remove the filters and remove the burnt out bulb Refit the filters ...