5019 300 00586
LIGHTING THE BURNERS
•
To ignite one of the burners, turn the relative knob anticlockwise to the maximum flame setting.
•
Press and hold the knob until the burner ignites.
•
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over,
etc.).
•
The control knob must not be pressed for more than 15 seconds. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before repeating the operation.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For optimum burner performance, observe the following
rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
2
1
3
1.
Removable grid
2.
4-crown burner
3.
4-crown burner control knob
Symbols
Tap closed
Max. flame
Min. flame
Burner
Pot Ø
4-crown burner
24 to 26 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
Note:
Before fitting a hood above the cooktop, please refer to the user manual for the correct distance.
INJECTOR TABLE
CATEGORY
II
2E+3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas used
Type of
burner
Injector
marking
Nominal
heating
capacity
(kW)
Nominal
consumption
Reduced heating
capacity
(kW)
Gas pressure
(mbar)
BE
FR
min.
nom.
max.
NATURAL GAS
(Methane)
G20
4-crown
139
3,50
333 l/h
1,95
1,55
17
20
25
NATURAL GAS
(Methane)
G25
4-crown
139
3,50
388 l/h
1,55
20
25
30
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
4-crown
90
3,20
233 g/h
1,55
20
28-30
35
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
4-crown
90
3,20
229 g/h
1,55
25
37
45
Type of gas used
Model configuration 1
BURNER
Nominal heating capacity
(kW)
Total nominal
consumption
Air necessary (m
3
) or the
combustion of 1 m
3
of gas
G20 20 mbar
4-crown
3,50
333 l/h
9,52
G25 25 mbar
4-crown
3,50
388 l/h
8,187
G30 28-30 mbar
4-crown
3,20
233 g/h
30,94
G31 37 mbar
4-crown
3,20
229 g/h
23,80
AKT 351
PRODUCT DESCRIPTION SHEET
EN
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.