AKT 775
COOKING HOB OPERATING INSTRUCTIONS
Destinations
GB
To ensure best use of the hob, please read these instructions carefully and keep them for future reference.
5019 319 01468
IT
UK
Operation of gas burners with safety and electric ignition
To light one of the burners:
•
Press and turn the corresponding knob anticlockwise to
the large flame symbol
.
•
At the same time, keep the knob pressed against the
control panel until the burner ignites
.
The igniter spark will light the burner.
•
Once the burner is lit, keep the knob pressed for about
10 seconds.
•
Release the knob.
If the burner fails to light, repeat the above steps.
Note:
The burner safety device shuts off the gas if the flame goes
out accidentally (sudden draughts, interruption in gas
delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If the
burner does not stay alight after this time has elapsed, wait at
least one minute before trying to light it again.
Important:
Improper use of the grates could scratch the hob: do not
place the grates upside down and/or slide them on the hob.
It is inadvisable to use:
•
cast iron grills or earthenware pots and pans
•
dissipators such as metal mesh etc.
•
two burners simultaneously for one container (e.g. fish
kettle).
HOB DIMENSIONS (mm)
NOTES: If a hood is installed above the hob, refer to the hood assembly instructions for the correct
distance to be respected.
1
3
2
4
6
7
5
1.
Removable grates
2.
Double crown wok burner
3.
Auxiliary burner
4.
Semi-rapid burner
5.
Double crown burner control knob
6.
Auxiliary burner control knob
7.
Semi-rapid burner control knob
Symbols
Solid disc
Tap closed
Large flame
Max. opening/max. delivery
Small flame
Min. opening or reduced delivery
INJECTORS TABLE
CATEGORY II2H3+
ELECTRIC SUPPLY: 230V ~ 50Hz
BEFORE USING THE HOB
These instructions are only valid for the countries whose
symbol is given on the dataplate (under the hob).
•
Keep the packing elements (plastic bags, polyurethane
foam, etc.) out of the reach of children, as they are a
potential source of danger.
•
Use a detergent recommended for cleaning the stainless
steel hob and remove and deposits of fat or food. Before
using the hob, make sure to remove any stickers.
•
Make sure the hob was not damaged during transport.
•
Make sure installation and the gas/electrical
connections are carried out by a qualified technician
according to the Manufacturer's instructions and in
compliance with the current local regulations.
SAFEGUARDING THE ENVIRONMENT
Packing
The packing materials are 100% recyclable and marked with
the recycling symbol (
).
Products
This appliance is marked in compliance with European
Directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE). By ensuring that this appliance is correctly
scrapped, the user can help prevent potentially harmful
consequences for the environment and the health of people.
The symbol
on the product or accompanying
documentation indicates that this product should not be
treated as domestic waste but must be taken to a suitable
centre for collection and recycling of electrical and electronic
equipment. Disposal must be carried out in compliance with
local regulations on waste disposal.
For further information on the treatment, recovery and
recycling of this product, contact your competent local office,
the household waste collection service or the shop where you
purchased the appliance.
Type of gas used
Type of
burner
Injector
marking
Rated
thermal flow
rate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min. rat.
max.
NATURAL GAS
(Methane)
G20
double crown
semirapid
auxiliary
140
95
78
3.50
1.65
1.00
333 l/h
157 l/h
95 l/h
1.55
0.35
0.30
17
20
25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
double crown
semirapid
auxiliary
93
67
50
3.50
1.65
1.00
254 g/h
120 g/h
73 g/h
1.55
0.35
0.30
20
28-30
35
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
double crown
semirapid
auxiliary
93
67
50
3.50
1.65
1.00
250 g/h
118 g/h
71 g/h
1.55
0.35
0.30
25
37
45
Type of gas used
Model
configuration
3 burners
Rated thermal flow
rate kW
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20
20 mbar
G30
28-30 mbar
G31
37 mbar
1 DC - 1 SR - 1 AUX
1 DC - 1 SR - 1 AUX
1 DC - 1 SR - 1 AUX
6.15
6.15
6.15
585 l/h
447 g/h
439 g/h
9.52
30.94
23.80