LIGHTING THE BURNERS
•
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting
.
•
Press the knob against the control panel to ignite the burner.
•
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling
over, etc.).
•
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the
following rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
-
In the case of pans with convex bottoms (WOK), use
the support grille provided, which should be
positioned only on the 4 ring burner.
1.
Removable panstand grids
2.
Auxiliary burner
3.
Semirapid burner
4.
Rapid burner
5.
Semirapid burner
6.
4 ring burner
7.
Auxiliary burner control knob
8.
Semirapid burner control knob
9.
Rapid burner control knob
10.
Semirapid burner control knob
11.
4 ring burner
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner
Pot Ø
4 ring
from 24 to 26 cm
Rapid
from 24 to 26 cm
Semirapid
from 16 to 22 cm
Auxiliary
from 8 to 14 cm
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE:
If the distance “A” between the wall cabinets is between 600 mm and 730 mm, the height “B”
must be a minimum of 520 mm. if the distance “A” between the wall cabinets is greater than
the width of the hob, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the hob, please refer to the hood instructions for the
correct distance.
INJECTOR TABLE
CATEGORY
II
2H3B/P
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas used
Type of
burner
Injector
marking
Rated
thermal
flowrate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min.
rat.
max.
NATURAL GAS
(Methane)
G20
4 ring
Rapid
Semirapid
Auxiliary
139
128
95
78
3.50
3.00
1.65
1.00
333 l/h
286 l/h
157 l/h
95 l/h
1.55
0.60
0.35
0.30
17
20
25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane)
G31
4 ring
Rapid
Semirapid
Auxiliary
95
87
67
50
3.50
3.00
1.65
1.00
254 g/h
218 g/h
120 g/h
73 g/h
1.55
0.60
0.35
0.30
25
30
35
Type of gas
used
Model
configuration
Rated thermal flow
rate kW
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G20 20 mbar
5 burners
10.8
1028 l/h
9.52
G30/G3130 mbar
5 burners
10.8
785 g/h
30.94