PRECAUTIONS FOR USE

Warning:

• Make sure to insert the power plug securely.

Insecure insertion of the plug may cause
electrocution or fire.

• Never unplug the machine while running.
• Do not damage the cord or use an unapproved

cord.

• Do not plug other electric appliances into the

same socket or use extension cords.

• Never operate the air conditioner with wet

hands.

• Do not pull the plug out by the cord. This could

cause the cord to overheat and catch fire.

• Turn off the air conditioner and pull out the plug

when cleaning the air conditioner. This will
prevent electrocution or injury.

• The rated voltage of this air conditioner is 220-

240V with a tolerance of ±22V for fluctuation.
The compressor will vibrate if the voltage is too
low, causing damage to the cooling system.

• If you notice anything unusual (e.g. burnt smell),

switch off the power supply immediately and
contact the Whirlpool Authorized Service
Center nearest you.
If the abnormal condition continues, the air
conditioner could be damaged and could also
cause electrocution or fire.

• Grounding: The unit must be reliably grounded.

The grounding cable must be connected to the
special grounding system in the building.
If the building does not have a grounding
system, ask an expert electrician to install one.
Never connect the grounding cable to a gas
pipe, water pipe, sewage pipe or other unless
the professional considers it reliable.

• Make sure to unplug air conditioner when not in

use for an extended period. Accumulation of
dust could cause heating or fire.

• Set the room temperature appropriately. The

difference between indoor and outdoor
temperature should be 5°C.
Appropriate adjustment of the temperature
setting serves to reduce consumption.

• When the air conditioner is running, do not

leave doors and windows open in the room.
This will prevent loss of effectiveness of the air
conditioner.

• Never block the air inlet or outlet of indoor and

outdoor unit, as this will decrease the effect of
the air conditioner or cause it to shut down or
even catch fire.

• Spray cans, chemicals and gas tanks must be

placed at least 1m away from the indoor and
outdoor unit; they could cause fire or explosion

• Make sure to mount the outdoor unit on a

sturdy base. If the base is damaged and
unsteady, the unit could fall and cause injury.

• Do not stand or place anything on the outdoor

unit. Persons or objects falling from the unit
could cause injuries.

• Do not repair the air conditioner yourself.

Incorrect repairs could cause electrocution or
fire. Contact the Whirlpool Authorized Service
Center nearest you for repairs.

• Adjust the air flow and direction properly. When

the air conditioner is running, you can adjust the
air flow direction by setting the upper/lower
guide louver position using the remote control
or handle.

• Never reach with your finger or a stick into the

indoor or outdoor unit.

• Never blow the air directly at pets or plants, as

this may harm them.

• Never spray water onto the unit or wash the air

conditioner with water.

• Never let the air conditioner blow on a heat

source. This could put the flame out and cause
carbon monoxide poisoning.

• To avoid any harm to your health, do not blow

the cold air on your body too long or lower the
room temperature too much.

• This air conditioner cannot be used for drying

clothes or chilling foods.

Warning:

• Do not cut or damage the power cords and

control lines. Any damaged power cords and
signal control lines of the air conditioner must
be replaced by qualified technicians with special
cords.

• Persistent abnormality indicates that the air

conditioner may be damaged with the
consequent risk of electric shock or fire. This
may cause an electric shock.

• To prevent fire always use a special power

supply circuit.

• Disconnect the air conditioner from the power

supply if it is to be left unused for a long period.

• For 18-23K, 230V, with a tolerable fluctuation of

±23V. The compressor is subject to strong
vibrations under very low voltages which can
damage the refrigerating system. Electrical
elements are easily damaged by high voltage.

Summary of Contents for AMD 064

Page 1: ...t as this will decrease the effect of the air conditioner or cause it to shut down or even catch fire Spray cans chemicals and gas tanks must be placed at least 1m away from the indoor and outdoor unit they could cause fire or explosion Make sure to mount the outdoor unit on a sturdy base If the base is damaged and unsteady the unit could fall and cause injury Do not stand or place anything on the...

Page 2: ...s very quickly Use this air conditioner with other heating equipment when outdoor temperatures are extremely low Defrost The outdoor unit heat exchanger may frost when the outdoor temperature is low humidity is high and the air conditioner has been running for some time resulting in inefficient heating In this case the appliance automatically defrosts and heating is suspended for 6 10 minutes Both...

Page 3: ...8 Sealing tape 9 Indoor outdoor power cord 10 Drain Pipe 10 9 5 6 7 8 2 1 4 3 6 Air inlet Air outlet Remote Control Indoor Unit Outdoor Unit Heat Cool Temperature On Dehumidify Signal receiver Air inlet Air outlet Images in the user instructions are based on external views of standard models shape and design vary according to the model ...

Page 4: ...he CLOCK icon will start to blink and you can set the time Description and Function of Remote Control Keys Note Be sure to point the remote control towards the signal receiver Check that there is no obstacle between the remote control and signal receiver Do not drop or throw the remote control Do not drop any liquid onto the remote control or expose it to direct sunlight or extremely hot temperatu...

Page 5: ... louver swings back and forth in all the five places as shown in the figure TIMER ON key Timer On setting ON flashes and will conceal numeral segment become timer on setting status Pressing or could adjust the numeral segment of time increase or decrease 1 minute per time within 5 seconds If you hold pressing or the numeral will change quickly after 2 second The way of the change is in the first 2...

Page 6: ...once will activate the SLEEP function and the SLEEP icon will appear Pressing again disables the SLEEP function On changing mode or starting stopping the unit the SLEEP function will be cancelled automatically The set temperature will rise max 1 C if the appliance operates in cooling mode for two hours then it will remain constant if room temperature is 26 C or above set temperature will not chang...

Page 7: ...use new batteries with old batteries or different types of batteries as this may cause the remote control to malfunction If you do not expect to use the remote control for some time take the batteries out to prevent leakage of battery acid in the remote control Operate the remote control within effective range Keep the remote control at least 1 meter from any TV set or hi fi equipment If the remot...

Page 8: ...shown by the arrow Pull the slots at the two ends of the front panel with force to remove the front panel 2 Cleaning the front panel Wash with a soft brush soaked in water and neutral detergent Wipe off the water and dry the panel Note To avoid discoloring or deformation do not wash with hot water over 45 C 3 Replacing the front panel depending on the model Place the rotary holder on two ends of t...

Page 9: ...filter as shown by the arrow Clamp the cover of the front panel securely Checks before Seasonal Use 1 Check the air inlet outlet on indoor and outdoor units for any blocking 2 Check the grounding cable for reliability 3 Check the battery of the remote control for replacement 4 Check the mounting frame of the outdoor unit for damage If damaged contact a Whirlpool Authorized Service Center Maintenan...

Page 10: ...ity are high This is because the indoor air is cooled quickly After a short time the fog will disappear as the indoor temperature and humidity decrease You may hear a slight crack when the air conditioner is started or stopped This is the sound of friction caused by expansion of the front panel or other parts due to the change of temperature Air conditioner does not run Is there a power failure Is...

Page 11: ...exchanger has more frost the air conditioner will activate the auto defrost function and the indoor unit will stop air blowing for 6 10 minutes During defrost water or steam may flow from the outdoor unit In dehumidify mode the fan on the indoor unit may stop to prevent evaporation of condensing water and rise of temperature Moisture on outlet grill If the air conditioner is left running in high h...

Page 12: ...nsation water can be easily discharged and the outdoor unit can be easily connected 3 Install out of the reach of children 4 Choose a place capable of bearing the weight of the indoor unit without increasing noise and vibrations 5 Ensure sufficient clearance and space for service and maintenance ensure the indoor unit is at least 2 3m from the floor 6 Choose a position at least 1 meter from any TV...

Page 13: ... As the air conditioning unit is a Class 1 electrical appliance reliable grounding measures must be taken 2 The yellow and green cable inside the air conditioner is for grounding and must not be used for other purposes or cut Do not tighten with tapping screws this could cause electrocution 3 The user power supply shall have a reliable grounding terminal It is prohibited to connect the grounding w...

Page 14: ...cm Air intake side AMD 064 AMD 065 50 cm or more Space to the cover 30 cm or above Space to the cover 30 cm or above Air inlet side 50 cm or above Space to the wall 200 cm or above Air outlet side 50 cm or more Space to the cover 30 cm or above Space to the cover 200 cm or above Air outlet side 50 cm or above Space to the wall 30 cm or above Air inlet side ...

Page 15: ...l a tapered hole Ø 55 2 To prevent the fitting pipe and the cable passing through the wall from being harmed and also to protect the hollow wall from rats it is necessary to install a wall pipe Installing Drainage Pipe 1 The flexible drainage pipe must be tilted downward to allow the water to drain 2 Make sure not to kink hump or distort drainage pipe in the layout and not to immerse the outlet in...

Page 16: ...necting cable Improper fastening may allow dust or water to enter or expose connecting terminal directly to external forces and fire or electrocution could occur Installing Indoor Unit Fitting pipe can come from four directions i e right rear right left and rear left 1 When installing the pipe on the left or right side trim off any extra pipe left at the pipe outlet stub on the base of the unit Se...

Page 17: ...orque may damage the nut Notes Connect the connecting pipe to the indoor unit first and then connect it to the outdoor unit Pay attention to the bending and layout when preparing the connecting pipe in order not to harm it Do not screw the joint nut too tightly otherwise leakage will be caused Hexagon Nut Tightening Torque Nlm Ø 6 15 20 Ø 9 5 31 35 Ø 12 50 55 Ø 16 60 65 Fitting Pipes of Indoor Uni...

Page 18: ... malfunction of some electric components After fixing cable ensure that leads between connection to fixed point have some space The connection pipes and the connection wirings of the units must be corresponding to each other respective The appliance shall be installed in accordance with national wiring regulations Do not install the outdoor unit where it is exposed to the sunlight Handling After h...

Page 19: ...fixing cable ensure that leads between connection to fixed point have some space The connection pipes and the connection wirings of the units must be corresponding to each other respective The appliance shall be installed in accordance with national wiring regulations Do not install the outdoor unit where it is exposed to the sunlight Handling After having removed the packaging check that the cont...

Page 20: ...cuum pump hose to the service valve 4 Operate the vacuum pump for 10 15 minutes until an absolute vacuum of 10 mm Hg has been reached 5 With the vacuum pump still in operation close the lowpressure knob on the vacuum pump coupling Stop the vacuum pump 6 Open the 2 way valve by 1 4 turn and then close it after 10 seconds Check all the joints for leaks using liquid soap or an electronic leak device ...

Page 21: ...ibrate or make noise Has gas leakage been checked May cause unsatisfactory cooling heating effect Is the thermal insulation of the unit sufficient May cause unsatisfactory cooling heating effect Is drainage smooth May cause condensation and dripping Is the main supply voltage the same as the rated voltage specified on the nameplate The unit may break down or components may burn out Are the lines a...