17
INSTALLATION OF THE OUTDOOR UNIT
Wiring
Wiring For Above 6000W Model (Above 21000BTU/h Model)
1.
Remove the self-tapping screws (2 pcs) on the
maintenance board and take out the maintenance
board.
2.
Loosen the self-tapping screws (2 pcs) on the fixing
clip to loosen the fixing clip.
3.
Loosen the fixing screw of the wire terminal board,
pass the power wire and signal wire through the
fixing clip. Then firmly fix the power wire and signal
wire on the terminal board with the fixing screw.
(Earth wire must be connected firmly.)
The cable wire can be led from the back hole of the
piping hole or ejecting hole.
Please utilize outdoor pipe support when the cable
wire is led from the backside.
4.
Tighten the self-tapping screw on the fixing clip.
5.
Install the maintenance board. After the pipes and
cable wire are installed, please seal the sponge
block as per drawing indication.
Outdoor unit terminal
Connecting cable
Maintenance
board
Terminal board
Fix the cable
wire with
anchor cable
Piping cover
Outdoor pipe support (Outdoor pipe
support is not required when leading the
cable wire from other places).
Maintenance
board
Back wiring
Right wiring
Ejecting hole
Piping cover
Sponge
Piping cover