background image

12

MODE AND FUNCTION DESCRIPTIONS

6th SENSE MODE

Press the 

button, the unit enters 

6th sense

mode directly regardless of the unit is on or off.
In this mode, temperature and fan speed are
automatically set based on the actual room
temperature.

Operation mode and temperature are
determined by indoor temperature.

Heat pump models

Cooling only models

Button is ineffective in Jet mode.

Note:

Temperature, airflow and direction are

controlled automatically in 6th sense mode.
However, a decrease or rise of up to 2°C can be
set with the remote control if you still feel
uncomfortable.

What you can do in 6th sense mode

Indoor

temperature

Operation

mode

Target

temperature

21°C or below

HEATING

22°C

21°C-23°C

FAN ONLY

23°C-26°C

DRY

Room

temperature

decrease 1.5°C

after operating

for 3 minutes

Over 26°C

COOLING

26°C

Indoor

temperature

Operation

mode

Target

temperature

26°C or below

DRY

Room

temperature

decrease 1.5°C

after operating

for 3 minutes

Over 26°C

COOLING

26°C

ON

 OFF

Your feeling

button

adjustment procedure

Uncomfortable because of unsuitable
air flow volume.

FAN

Indoor fan speed alternates among High, Medium
and Low each time this button is pressed.

Uncomfortable because of unsuitable
flow direction.

Swing

Press it once, the vertical adjustment louver swings
to change vertical airflow direction. Press it again,
swings stops. For horizontal airflow direction please
refer to the chapter "Airflow direction control".

Summary of Contents for AMD034

Page 1: ...st be performed by a qualified technician in compliance with the producer s instructions and following local safety norms Do not repair or replace any parts of the appliance unless it is specifically written in the user instructions The grounding of this appliance is compulsory Make sure that the power supply cord is long enough to allow the right connection Do not use any extension cord for power...

Page 2: ...u will help to prevent potentially negative consequences for the environment and for human health The symbol on the product or on the documents accompanying the product indicates that this appliance should not be treated as household waste but must be given to the appropriate local gathering place where electric and electronic appliances are stored and recycled SAFEGUARDING THE ENVIRONMENT AIR CON...

Page 3: ...stment Louver 8 Horizontal Adjustment Louver 9 Air Filter 10 Remote Control Outdoor unit 11 Air Intake 12 Pipes and Power Connection Cord 13 Drain Hose Note Condensate water drains at COOLING or DRY operation 14 Air Outlet Images in the user instructions are based on external views of standard models shape and design vary according to the model ON OF F ...

Page 4: ... lights up during sleep mode Filter monitor indicator 5 It flashes when the filter needs to be cleaned Filter monitor indicator flashes after 240 hours of usage as reminder to clean the filter After filter cleaning press the reset button located on the indoor unit behind the front panel in order to interrupt the flashing of the filter monitor indicator Emergency ON OFF button 6 Used to control the...

Page 5: ...nsmit signal of the actual room temperature around it to the indoor unit every 10 minutes Therefore please keep the remote controller in a location where it can transmit the signal to the indoor unit properly Press once to set and press again to cancel 10 CLOCK BUTTON Used to set the current time 11 12 TIMER BUTTON Used to set or cancel the timer operation 13 JET BUTTON Used to start or stop the f...

Page 6: ...es taking more than 3 minutes all presetting will be cancelled and timer will display Zero How to remove the batteries Remove the battery cover in the direction of the arrow Press the positive pole of the battery softly with your fingers then draw the batteries out of the compartment All this should be done by adults children are forbidden to remove the batteries from the remote control in order t...

Page 7: ...ally FAN button is ineffective in this case 3 Setting temperature Press once to raise temperature setting by 1 raise C Press once to lower temperature setting by 1 lower C Note Heating mode is NOT available for cooling only models 4 Turning on Press button when the appliance receives the signal the RUNNING indicator of the indoor unit lights up During mode changes wait a few seconds and repeat the...

Page 8: ...essing the SWING button again when the louvers swing to a suitable angle as desired Horizontal airflow control with hands Turn the control rods of the horizontal adjustment louvers to change horizontal air flow as shown Note The shape of the unit may look different from that of the air conditioner you have selected A Do not turn the vertical adjustment louvers manually otherwise malfunction may oc...

Page 9: ... Indoor temperature Operation mode Target temperature 21 C or below HEATING 22 C 21 C 23 C FAN ONLY 23 C 26 C DRY Room temperature decrease 1 5 C after operating for 3 minutes Over 26 C COOLING 26 C Indoor temperature Operation mode Target temperature 26 C or below DRY Room temperature decrease 1 5 C after operating for 3 minutes Over 26 C COOLING 26 C ON OFF Your feeling button adjustment procedu...

Page 10: ...for 3 hours Note In cooling mode if room temperature is 26 C or above set temperature will not change Note Heating is NOT available for cooling only air conditioner JET mode JET mode is used to start or stop fast cooling Fast cooling operates at high fan speed changing the set temperature automatically to 18 C JET mode can be set when the appliance is in operation In JET mode you can set airflow d...

Page 11: ...se or decrease the time setting by 10 minutes Press the or button for a longer time to increase or decrease the time by 1 hour Note If you don t see the time in 10 seconds after you press TIMER ON button the remote control will exit the TIMER ON mode automatically ii When your desired time displayed on LCD press the TIMER ON button and confirm it A beep can be heard ON stops flashing The TIMER ind...

Page 12: ...y and remove the air filter 1 Open the front panel 2 Press the handle of the filter gently 3 Slide out the filter 2 Cleaning and refitting the air filter If the filter is very dirty clean it with a solution of lukewarm water and neutral detergent After cleaning let it dry 3 Close the front panel Fig A Fig B PROTECTION Operating condition The protective device maybe trip and stop the appliance in t...

Page 13: ... Is the protection device or fuse blown Please wait for 3 minutes and start again protection device may be preventing unit to work Are the RC batteries low Is the plug not properly plugged No cooling or heating air Is the air filter dirty Are the intakes and outlets of the air conditioner blocked Is the temperature set properly Ineffective control Has there been a strong interference from excessiv...

Page 14: ...ccordance with the national wiring standards by authorized service people only Distance from wall should be over 50mm Distance from ceiling should be over 50mm Distance from floor should be over 2000mm Distance from the wall should be over 50mm Air intake distance from the wall should be over 250mm Air intake distance from the wall should be over 250mm Air outlet distance from the wall should be o...

Page 15: ... Install in a convenient and well ventilated place Avoid installing it where flammable gas could leak Observe the required distance from the wall The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters with additional refrigerant charge Do not install the outdoor unit in a dirty or greasy place near a vulcanization gas exit Avoid installing it at the road...

Page 16: ...ined downward toward outside Install a sleeve through the wall hole to keep the wall tidy and clean 3 Indoor Unit Piping Installation Fit the piping liquid and gas pipe and cables through the wall hole from outside or fit them from inside after completing indoor piping and cables connections so as to connect to outdoor unit Decide whether saw off the plastic part in accordance with the piping dire...

Page 17: ...ain hose is connected to the drain pipe make sure to be thermally insulated when passing it through the indoor unit When the piping is directed to the right piping power cord and drain pipe should be thermally insulated and fixed at the rear of the unit with a piping fixer A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Thermal insulation Wrapped with vinyl type La...

Page 18: ...the access door from the unit by loosening the screw Connect the wires to the terminals on the control board individually as follows 2 Secure the power connecting cord on the control board with cable clamp 3 Refit the access door in the original position and tighten the screw 4 Use a recognized circuit breaker for 24K model between the power source and the unit A disconnecting device to adequately...

Page 19: ...ross sectional area Type Normal cross sectional area 7K 9K 12K H05VV F 1 0 1 5mm X3 H07RN F 1 0 1 5mm X3 H05RN F 0 75mm X2 Heat pump To indoor 18K H05VV F RVV 1 5 2 0mm X3 H07RN F 1 5mm X3 H05RN F 0 75mm X2 Heat pump To indoor 24K H07RN F 2 5mm X3 H07RN F 1 5mm X3 Heat pump 1 5mm X4 Cooling only H05RN F 0 75mm X3 Heat pump To outdoor WIRING DIAGRAM Make sure that the colour of wires of the outdoor...

Page 20: ... should be well wrapped with a wrapping tape and the connector should be put inside the unit Defrost wire indoor Defrost wire outdoor HEAT PUMP power connecting cord 1 power connecting cord Indoor unit Terminal Outdoor unit Terminal Brown Blue Brown Blue Brown Blue Brown Blue Yellow Green Yellow Green N L L 1 L 1 L 3 L 3 L 2 L 2 N N L L HEAT PUMP Power connecting cord 1 Power connecting cord Indoo...

Page 21: ...e 2 way and 3 way valve Connect the pipes to the 2 way and 3 way valves separately according to the required torque 4 Outdoor Unit Cable Connection see previous page Air purging Air containing moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units evacuate air and moisture from refrigerant cycle using a vacuum pump as s...

Page 22: ...f the air conditioner There must be an air break switch After installing the consumer must operate the air conditioner correctly according to this manual keep a suitable storage for maintenance and move of the air conditioner in the future Type of fuse used on indoor unit controller is Φ 5x20 with rating 2 5A 250V or 3 15A 250V Caution Mount with the lowest moving parts of indoor unit at Least 2 4...

Reviews: