background image

Summary of Contents for CGM2941TQ

Page 1: ...INSTALLATIONINSTRUCTIONS COMMERCIAL DRYER Gas 12 Volt 60 Hz or Electric 12 24 Volt 60 Hz Table of Contents 2 8563800 www roper com ...

Page 2: ...safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately follow instructions You can be killed or seriously injured if you don t follow instructions All safety messages will tell yo...

Page 3: ...unless specifically recommended in this Use and Care Guide or in published user repair instruc tions that you understand and have the skills to carry out Do not dry articles that have been previously cleaned in washed in soaked in or spotted with gasoline dry cleaning solvents other flammable or explosive substances as they give off vapors that could ignite or explode Do not allow children to play...

Page 4: ...t installation of clothes dryers in garages closets or sleeping quarters Contact your local building inspector Make sure that lower edges of the cabinet plus the back and bottom sides of the dryer are free of obstructions to permit adequate clearance of air openings for combustion air See Recessed Area and Closet Installation Instructions below for minimum spacing requirements NOTE The dryer must ...

Page 5: ...acceptable Product Dimensions 29 73 7 cm dryer 4 3 4 12 1 cm _ _29 73 7 cm _ _ 1 m I I BACK VIEW ELECTRIC1_ 40 6cm 13 4 10 2 cm dia _ 2k I 2_ 18 3 8 _ 46 7 cm SIDE VIEW 27 1 4 69 2 cm 1 1 4 non coin operated models 7 1 8 18 1 cm coin operated models 7 7 8 20 cm Product Dimensions 27 68 6 cm dryer 1 1 4 3 2cm 35 88 9 cm 1 2 5 cm _ 27 68 6 cm t 88 6 cm 37 BACK VIEW 94cm 13 4 10 2 cm dia 4 3 4 i_GAS ...

Page 6: ...local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition The National Electric Code requires a 4 wire supply connection for homes built after 1996 dryer circuits involved in remodeling after 1996 and all mobile home installations If codes permit and a separate ground wire is used it is recommended that a qualified electrical installe...

Page 7: ...it part numbers are listed on the gas valve burner base Gas Supply Line Recommended method Provide a gas supply line of rA rigid IPS pipe to the dryer location Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON _ tape With LP gas piping or tubing size can be 1 2 minimum Usually LP gas suppliers determine the size and materials used in the system Alternate method T...

Page 8: ...the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid metal or flexible metal vent Plan installation to use the fewest number of elbows and turns Exhaust Air Flow A Better B Good Allow as much room as possible when using elbows or making turns Bend vent gradually to avoid kinking Vent outlet is located at the center of...

Page 9: ...ther vents The maximum angle of each vent entering the main vent should be no more than 30 air flow _ B _ A Individualdryervent B Main vent Keep air openings free of dry cleaning fluid fumes Fumes create acids which when drawn through the dryer heating units can damage dryers and loads being dried A clean out cover should be located on the main vent for periodic cleaning of the vent system if an e...

Page 10: ...ipe joint compound resistant to the action of L R gas for gas connections If flexible metal tubing is used be certain there are no kinks 3 Open the shutoff valve in the gas supply line 4 Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found f Using a 4 10 2 cm clamp connect vent to exhaust outlet in dryer If connecting ...

Page 11: ... in hand check the ridges for a diamond marking That s how far the leg is supposed to go into the hole 5 Start to screw the leveling legs into the holes by hand Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark Now stand the dryer up 6 Remove the ser...

Page 12: ...upply cord must have four No 10 copper wires and match a four wire receptacle of NEMA Type 14 30R The fourth wire ground conductor must be identified by a green cover and the neutral conductor by a white cover 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver colored terminal block screw 7 Connect...

Page 13: ...in relief screw E Neutral center wire F Appliance neutral ground wire Use this method where local codes do not permit connecting neutral ground wire to neutral wire 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the power supply cord under ...

Page 14: ...re is not available Direct Wire Four wire electrical connection _ 31 2 8 9 cm _1 A I 1 2 5 ore 4_ I ofwires 1o I strippedof _ _ disconnect I insulation Shapeends of wires into a hook Strip 5 12 7 cm of outer covering from end of cable Leave green or bare ground wire at 5 12 7 cm Cut 1 3 8 cm from 3 remaining wires Strip insulation back 1 2 5 cm A _4 conduit connector B Neutral white or center C Gr...

Page 15: ... terminal block screws Tighten screws 8 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw 9 After reattaching the terminal cover connect a separate copper ground wire from the external ground connector screw to an adequate ground If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that ...

Page 16: ...r reconnect power Maintenance instructions Clean lint screen after each cycle Removing accumulated lint From inside the dryer cabinet Lint should be removed every 2 years or more often depending on dryer usage Cleaning should be done by a qualified person From the exhaust vent Lint should be removed every 2 years or more often depending on dryer usage If you need assistance The Commercial Laundry ...