6)  WATER CONNECTIONS 
 

INLET: 

The  pressure  in  the  main  water  supply  must  be  between  50  and  500  Kpa,  in  the  event  the 
pressure is higher, a pressure reducer must be installed upstream from the appliance. 

¾

” attachments are used. 

OUTLET: 

¾

” attachments are used. In the event the outlet pipe needs extending, only heat resistant piping 

must be used with a fixed diameter of 

¾

”. The outlet pipe must flow into an open drain, to avoid 

polluting the appliance. 
 
7)  GENERAL OPERATING INSTRUCTIONS 
 

Please  read  these  instructions  carefully,  as  they  give  the  basic  safety,  operating  and 
maintenance instructions for the appliance. 

 
Before leaving the factory, the appliance underwent very strict tests and controls by our qualified 
staff. Any repair work that may be required must only be performed by qualified persons. 
We strongly recommend contacting the authorised centre where you purchased your appliance, 
giving  clear  details  about  the  problem  and  the  construction  details  given  on  the  data  plate,  to 
ensure that precise and specific servicing assistance can be supplied. 
 
BAIN-MARIE UNITS 
 
The  appliance  must  not  be  used  unless  there  is  sufficient  water  in  the  tank,  as  given  in  the 
instructions on page 11. 
 
HEATED GLASS TOPS 
 

WARNINGS: 

a)  Should there be even the smallest sign of breakage in the heated surface, the appliance 

must be immediately disconnected from the mains and our service department should be 
contacted. 

b)  The  hardened  glass  surface  must  be  protected  against  impact,  knocks  and  violent 

mechanical and thermal stress. At the end of each day, the top must be carefully cleaned 
(refer to “CLEANING AND CARE”) to guarantee long life for the appliance. 

 

At  the  end  of  each  day’s  work,  the  appliance  must  be  turned  off  and  disconnected  from 
the mains upstream. 

 
The appliance may be supplied on 4 castors, 2 of which have brakes. 
The installer must install a coiled lead and in the event the appliance needs moving, it must be 
turned off and disconnected from the mains beforehand. 
 
Failure to comply with this rule could jeopardize safety of both the appliance and the operator 
 
The manufacturer declines all responsibility for any alterations made to the original functions of 
the appliance, for failure to observe the instructions or for any alterations or additions made to the 
devices. 
 
 

Summary of Contents for Design Series

Page 1: ... 325 ASE 326 ASE 327 ASE 328 ASE 329 ASE 330 ASE 331 ASE 332 ASE 333 ASE 334 ASE 335 ASE 336 ASE 337 ASE 338 ASE 339 ASE 340 ASE 341 ASE 342 ASE 343 ASE 344 ASE 345 ASE 346 ASE 347 ASE 348 ASE 349 ASE 350 ASE 351 ASE 352 ASE 353 ASE 354 ASE 355 ASE 356 ASE 357 ASE 358 ASE 359 ASE 360 ASE 022 ASE 023 ASE 024 ASE 025 ASE 026 ASE 027 ASE 028 ASE 029 ASE 030 ASE 031 ASE 032 ASE 033 ASE 034 ASE 035 ASE...

Page 2: ...NSTRUCTIONS pg 5 8 CLEANING AND CARE pg 6 9 CONTROL PANEL pg 6 10 USE AND FUNCTIONS pg 7 The manufacturer declines all responsibility for any printing or copying errors in this handbook The manufacturer reserves the right to make any changes deemed necessary or useful to its products without altering the basic features All rights reserved No part of this publication may be reproduced or photocopie...

Page 3: ...s been caused during transport 4 Before positioning and installing the appliance check that the output and voltage features given on the data plate correspond to the power supply in the installation site The data plate is on the bottom right of the serving side 5 In the event of problems immediately turn the machine off and disconnect or close all connections 2 SPECIAL WARNINGS FOR POSITIONING AND...

Page 4: ...t The main switch upstream from the appliance must be in an easily reached position close to the appliance itself The installer must be supplied with the suitable electric lead H05 RN F5x1 5mm which must be firmly fixed in the cable clamp The single wires must be joined to the corresponding terminals the earth wire must be longer than the others to ensure that it can only be disconnected in the ev...

Page 5: ... can be supplied BAIN MARIE UNITS The appliance must not be used unless there is sufficient water in the tank as given in the instructions on page 11 HEATED GLASS TOPS WARNINGS a Should there be even the smallest sign of breakage in the heated surface the appliance must be immediately disconnected from the mains and our service department should be contacted b The hardened glass surface must be pr...

Page 6: ...uter surfaces following the direction of the brushed satin finish In the event the appliance will not be used for a long time rub it well with a cloth soaked in Vaseline oil to spread a protective film all over the room should be periodically ventilated as well Warning the appliance must be disconnected from the mains in the event of long periods without use 9 CONTROL PANEL F E D C B A H G KEY A M...

Page 7: ...t the required temperature levels on the respective thermostats 6 To maintain correct constant temperature levels for the dishes we advise setting the thermostats as follows 90 C for the tank and heated glass surface and 70 C for the heated cabinet 7 The bain marie units are designed for containing the dishes in GN basins measuring h 150mm and h 100mm 8 To avoid remaining without water check the l...

Reviews: