- 17 -
IGNITION SYSTEM OPERATION
OHMS LAW:
I = E/R
AMPS = VOLTAGE DIVIDED BY RESISTANCE
A cold ignitor has a high resistance. When the oven control relay closes—
IGNITOR
OVEN CONTROL
RELAY
BIMETAL
COIL
N
L1
LO
HI
OHMS
Current flows through the ignitor and the bimetal coil.
IGNITOR
OVEN CONTROL
RELAY
BIMETAL
COIL
N
L1
LO
HI
OHMS
High ignitor resistance causes low current flow through the bimetal coil. As the ignitor heats up, its
resistance decreases.
IGNITOR
OVEN CONTROL
RELAY
BIMETAL
COIL
N
L1
LO
HI
OHMS
LO
HI