Approved Built-In Oven and Induction Cooktop Combinations

For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the 
bottom of the cooktop burner box.

NOTE: For undercounter installation, it is recommended that the junction boxes for oven and cooktop be located in the adjacent right or 
left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface 
to pass the appliance cable through to the junction box. On models with Steam-Assist, it will be necessary to drill a 1" (1.3 cm) 
minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing through to the undersink 
water filter. If water supply tubing hole is drilled on the same side as the oven cable hole, a minimum of 2" (5.1 cm) is required between 
the 2 holes.

A. 24" (61 cm) cabinet depth
B. 25" (63.5 cm) countertop depth

C. Recommended oven and cooktop junction box locations
D. Allow 

⁵⁄₈

" (1.6 cm) for oven trim to overlap on each side.

E. 27¾" (70.5 cm) minimum cutout height

F. 36" (91.4 cm) from cabinet base to countertop

G. 3

⁵⁄₈

" (9.2 cm) from floor

H. See Cutout Dimensions chart.

CUTOUT DIMENSIONS

Oven Size

Oven Cutout Dimension

24" (61 cm)

22

¹⁄₂

" (57.2 cm)

27" (68.6 cm)

25

¹⁄₂

" (64.8 cm)

30" (76.2 cm)

28½" (72.4 cm)

A

E

F

G

H

B

C

C

D

Summary of Contents for GBD309PV Series

Page 1: ... bottom of cutout to floor D 28 72 4 cm cutout width E 1 3 8 cm min bottom of cutout to top of cabinet door F 49 126 4 cm min cutout height A B C D E F n e v O e l b u o D r o e l g n i S w e i V e d i S t e n i b a C A 23 59 1 cm min cutout depth B 23 58 4 cm recessed oven depth C Oven front D Recessed oven E Cabinet A B C D E Electrical Requirements Oven must be connected to the proper electrica...

Page 2: ... for oven and cooktop be located in the adjacent right or left cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to pass the appliance cable through to the junction box On models with Steam Assist it will be necessary to drill a 1 3 cm minimum diameter hole in the upper right or left rear corner of the side wall to pas...

Page 3: ... Assist it will be necessary to drill a 1 1 3 cm minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing through to the undersink water filter If water supply tubing hole is drilled on the same side as the oven cable hole a minimum of 2 5 1 cm is required between the 2 holes A 24 61 cm cabinet depth B 25 63 5 cm countertop depth C Recommended o...

Page 4: ...d between the 2 holes The upper shaded areas are recommended locations for recessed junction box for 120 volt grounded outlet for cooktop Lower shaded areas are recommended locations for flexible or rigid gas pipe installation The gas pipe can be installed on either side of the cutout and either through the floor or through the wall A 24 61 cm cabinet depth B 1 2 5 cm clearance to bottom of counte...

Page 5: ...4 Notes ...

Page 6: ...recommande que les boîtiers de connexion pour four et table de cuisson soient situés dans le placard adjacent à droite ou à gauche Un trou de diamètre 1 2 5 cm ou plus doit avoir été percé dans la partie supérieure de l angle arrière gauche ou droit de la surface de la paroi latérale pour le passage du câble d alimentation de l appareil jusqu au boîtier de connexion Sur les modèles avec injection ...

Page 7: ...faudra percer un trou d un diamètre de 1 1 3 cm minimum dans l angle supérieur droit ou inférieur gauche de la paroi latérale pour le passage de la canalisation d eau jusqu au filtre à eau sous l évier Si le trou de la canalisation d eau est percé du même côté que celui du câble du four une distance minimale de 2 5 1 cm est nécessaire entre les 2 trous A Profondeur de placard 24 61 cm B Profondeur...

Page 8: ... grisées supérieures pour la prise de 120 volts reliée à la terre du boîtier de connexion encastré de la table de cuisson On recommande l installation de la canalisation de gaz flexible ou rigide dans la zone ombrée inférieure La canalisation de gaz peut être installée d un côté ou de l autre de l ouverture découpée à travers le plancher ou à travers le mur A Profondeur de placard 24 61 cm B Dégag...

Page 9: ...W10373101A 2011 All rights reserved Tous droits réservés 1 11 Printed in U S A Imprimé aux É U ...