Recommended standard fittings
Accesorios estándar recomendados
3-1/4" x 10" vent system:
1 - 3-1/4" x 10"
90° elbow
= 25 ft.
1 - wall cap
= 40 ft.
8 feet straight
= 8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6" vent system
Sistema de salida de aire de 6"
3-1/4" x 10" vent system
Sistema de salida de aire de 3-1/4" x 10"
6" vent system:
1 - transition
= 5 ft.
2 - 90° elbows
= 20 ft.
1 - wall cap
= 40 ft.
8 feet straight
= 8 ft.
Length of 6" system = 73 ft.
3-1/4" x 10"
90° elbow
Codo de 90° y
3-1/4" x 10"
90° elbows
codo de 90°
transition
transición
wall cap
caperuza de
pared
6 ft.
6 pies
2 ft. (2 pies)
6 ft.
6 pies
2 ft. (2 pies)
3-1/4" x 10" to 6" = 5 ft.
De 3-1/4" x 10" a 6" =
5 pies
3-1/4" x 10" roof cap = 24 ft.
Caperuza de cielo raso de
3-1/4" x 10" = 24 pies
3-1/4" x 10"
90
°
elbow = 25 ft.
Codo de 90
°
y 3-1/4" x
10" = 25 pies
90
°
elbow = 10 ft.
Codo de 90
°
=
10 pies
3-1/4" x 10" wall cap
= 40 ft.
Caperuza de pared
de 3-1/4" x 10"=
40 pies
3-1/4" x 10" flat
elbow = 10 ft.
Codo plano de 3-1/4"
x 10" = 10 pies
45
°
elbow = 5 ft.
Codo de 45
°
=
5 pies
Recommended vent length:
Use 3-1/4" X 10" rectangular or 6" round vent.
The total length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceed the
equivalent of 140 feet of 3-1/4" X 10" rectangular or 6"
diameter round vent.
For best performance, use no more than three 90 degree
elbows.
To calculate the length of system you need, add the
equivalent feet for each vent piece used in the system. See
the following examples:
continued from page 7
If the existing vent is round, a rectangular-to-round adapter
must be used and a rectangular 3" extension vent between
the damper assembly and adapter must be installed to
prevent damper from sticking.
Sistema de salida de aire de 3-1/4" x 10":
1 - Codo de 90°
y 3-1/4" x 10"
= 25 pies
1 - Caperuza de pared
= 40 pies
8 pies recto
= 8 pies
Longitud de un
sistema de 3-1/4" x 10" = 73 pies
Sistema de salida de aire de 6"
1 - transición
= 5 pies
2 - codos de 90°
= 20 pies
1 - caperuza de pared
= 40 pies
8 pies recto
= 8 pies
Longitud de un
sistema de 6"
= 73 pies
Longitud recomendada del conducto de salida de aire:
Use un conducto de salida de aire rectangular de 3-1/4" x 10"
o redondo de 6".
La longitud total del sistema de salida de aire, incluyendo el
conducto de salida de aire recto, el codo, las transiciones, las
caperuzas de pared o cielo raso no deben exceder el
equivalente a 140 pies de conducto rectangular de salida de
aire de 3-1/4" x 10" o conducto redondo de 6" de diámetro.
Para mejores resultados, no use más de tres codos de 90°.
Para calcular la longitud del sistema que necesita, agregue la
equivalencia en pie para cada pedazo de conducto usado en el
sistema. Vea los siguientes ejemplos:
Si el actual conducto de salida de aire es redondo, debe usarse
un adaptador de rectangular a redondo y un conducto de
extensión rectangular de 3" entre el conjunto de la compuerta
y se debe instalar el adaptador pare evitar que la compuerta se
atasque.
3-1/4" x 10" to 6" round vent
transition
transición de conducto de salida
de aire redondo de 3-1/4" x 10"
a 6"
3" minimum height (required
for damper to fully open)
Altura mínima de 3”
(necesaria para que la
compuerta se abra
completamente)
wall cap
caperuza
de pared
roof cap
caperuza de
cielo raso
6" min. diameter round vent
conducto de salida de aire
redondo de 6" de diámetro
mínimo
elbow
codo
Round vent transition
Transición de conducto de salida de aire redondo
For wall or roof venting methods:
Choose between roof venting or wall venting.
If the wall exhaust method is chosen, be sure that there is
proper clearance within the wall for the exhaust vent.
Vent materials needed for installation are not included.
Wall and roof caps must have back-draft damper.
We recommend:
✔
using rigid metal vent.
✔
that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
✔
that size of vent should be uniform.
✔
using duct tape to seal all joints in the vent system.
✔
using caulking compound to seal exterior wall or roof
opening around cap.
✔
two elbows should not be installed together.
We do NOT recommend:
✔
flexible metal vent.
NOTE:
If flexible metal vent must be used, calculate each
foot of flexible metal vent as two feet of rigid metal vent.
Flexible metal elbows count twice as much as standard
elbows.
Para métodos de salida de aire a través de la pared o el
cielo raso:
Decida entre instalar la salida de aire a través del cielo raso o
de una pared.
Si se decide por el método de salida de aire a través de la
pared, asegúrese de que haya el espacio adecuado dentro de
la pared para el conducto de salida de aire.
No se incluyen los materiales del conducto de salida de aire
que se necesitan para la instalación.
Las caperuzas para cielo raso y pared deben tener
compuerta de contratiro.
Recomendamos:
✔
usar un conducto de salida de aire metálico y rígido.
✔
que la longitud del conducto de salida de aire y el número
de codos se mantengan a un mínimo para lograr un
rendimiento eficiente.
✔
que las dimensiones del conducto sean uniformes.
✔
usar cinta para conducto para sellar todas las uniones en el
sistema de salida de aire.
✔
usar masilla para calafatear para sellar la pared exterior o la
abertura en el cielo raso alrededor de la caperuza.
✔
no se deben instalar dos codos juntos.
No recomendamos:
✔
conducto de salida de aire metálico flexible
NOTA:
si debe usarse un conducto metálico flexible, calcule
cada pie de conducto metálico flexible como si fueran dos pies
de conducto metálico rígido. Los codos de metal flexible hacen
por dos codos estándar.
Roof venting
Salida de aire por el cielo raso
Wall venting
Salida de aire por la pared
roof cap
caperuza de cielo raso
3-1/4" x 10" through-the-roof
a través del cielo raso por un orificio
de 3-1/4" x 10
3-1/4" x 10" through-the-wall
a través de la pared por un
orificio de 3-1/4" x 10
wall cap
caperuza de pared
viene de la página 7