4-18
REMOVING THE LINE FUSE HOLDER AND
THE MAGNETRON THERMOSTAT
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug microwave oven or disconnect
power.
2. Remove the control panel from the oven
(see page 4-14 for the procedure).
4.
To remove the magnetron thermostat:
a) Disconnect the two wires from the mag-
netron thermostat terminals.
b) Remove the screws from the magnetron
thermostat and remove the thermostat.
3.
To remove the line fuse holder:
a) Remove the line fuse from the fuse
holder.
b) Disconnect the two wire connectors
from the fuse holder terminals.
Magnetron Thermostat
c) Remove the screw from the fuse holder
and remove the holder from the oven.
Line Fuse
BK and RD
Wires
BRN Wire
Fuse Holder Screw
Magnetron
Thermostat
Screws
WH Wire
WH and GY Wires