3-3
850W
WARMING
DRAWER
BK
OR/BK
P3-1
P3-2
W
L1
N
Warming Drawer
Sensor
The warming drawer is accessed through the
electronic oven control. It operates an 850 watt
heating element across 120 VAC (L1 to Neu-
tral) that maintains a temperature of between
108 and 195 degrees. As you turn the warming
drawer on, it will default to the main setting of
108 degrees (LOW). Other warming drawer
temperatures may also be programmed, as
shown in the chart. The temperature of the
drawer is controlled by a sensor that is similar
to the main oven sensors. The warming drawer
sensor resistance is approximately 100 K
Ω
at
room temperature.
NOTE: To cancel the warming drawer opera-
tion, press the DRAWER OFF keypad.
The warming drawer is supplied with an insu-
lated liner that maintains the proper tempera-
ture within the drawer. The chart, shown above,
indicates the warming drawer temperatures
with the liner in place. If the liner is removed,
the operating temperatures will increase by
10
°
to 20
°
F. Do not use the warming drawer
liner inside the oven.
TEMPERATURE
°°°°
F
108
LOW
140
2
160
3
180
4
195
HI
SETTINGS
WARMING DRAWER