6

Laundry tub drain system

Minimum capacity: 20 gal. (76 L). Top of laundry tub must  

be at least 30" (762 mm) above floor; install no higher than

54" (1.37 m) from bottom of dryer.

IMPORTANT:

 Only 4.5" (114 mm) of drain hose should lay

on side of laundry tub. Do not lay the hose at the bottom of tub.

ELECTRICAL REQUIREMENTS –  

U.S.A. ONLY

It is your responsibility:

 

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate and  

in conformance with the National Electrical Code, ANSI/ 

NFPA 70 – latest edition and all local codes and ordinances. 

 

The National Electrical Code requires a 4-wire power supply 

connection for homes built after 1996, dryer circuits involved  

in remodeling after 1996, and all mobile home installations. 

 

A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.

 

To supply the required 3- or 4-wire, single-phase, 120/240 V, 

60 Hz, AC-only electrical supply (or 3- or 4-wire, 120/208 V 

electrical supply, if specified on the serial/rating plate) on a 

separate 30 A circuit, fused on both sides of the line. Connect 

to an individual branch circuit. Do not have a fuse in the neutral 

or grounding circuit.

 

Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that  

the ground path is adequate.

Remove the U-bend at the end of the drain hose by cutting  

the hose at the end of the U-bend for the floor drain system  

as shown in the picture above. 

NOTE:

 Cut hose so that no more than 4.5" (114 mm) of the hose 

is in the floor drain to avoid siphoning.

Floor drain system

4.5"

(114 mm)

4.5"

(114 mm)

max. 54"

(1372 mm)

min. 30"

(762 mm)

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) 

and be:

 

Flexible armored cable or nonmetallic sheathed copper cable 

(with ground wire), covered with flexible metallic conduit.  

All current-carrying wires must be insulated.

 

10-gauge solid copper wire (do not use aluminum) at least  

5 ft. (1.52 m) long.

Then choose a 4-wire power supply cord with 

ring or spade terminals and UL Listed strain 

relief. The 4-wire power supply cord, at least 

4 ft. (1.22 m) long, must have four 10-gauge 

copper wires and match a 4-wire receptacle of 

NEMA Type 14-30R. The ground wire (ground 

conductor) may be either green or bare. The 

neutral conductor must be identified by a white 

cover.

Then choose a 3-wire power supply cord with 

ring or spade terminals and UL Listed strain 

relief. The 3-wire power supply cord, at least 

4 ft. (1.22 m) long, must have three 10-gauge 

copper wires and match a 3-wire receptacle  

of NEMA Type 10-30R.

4-wire receptacle

(14-30R)

3-wire receptacle

(10-30R)

If your outlet looks like this:

Electrical Connection

To properly install your dryer, you must determine the type of 

electrical connection you will be using and follow the instructions 

provided for it here.

 

This dryer is manufactured ready to install with a 3-wire 

electrical supply connection. The neutral ground conductor  

is permanently connected to the neutral conductor (white wire) 

within the dryer. If the dryer is installed with a 4-wire electrical 

supply connection, the neutral ground conductor must be 

removed from the external ground connector (green screw), 

and secured under the neutral terminal (center or white wire) 

of the terminal block. When the neutral ground conductor is 

secured under the neutral terminal (center or white wire) of the 

terminal block, the dryer cabinet is isolated from the neutral 

conductor. The green ground wire of the 4-wire power cord 

must be secured to the dryer cabinet with the green  

ground screw.

 

If local codes do not permit the connection of a neutral  

ground wire to the neutral wire, see the “Optional External 

Ground for 3-Wire Connection” section.

 

A 4-wire power supply connection must be used when the 

appliance is installed in a location where grounding through  

the neutral conductor is prohibited. Grounding through the 

neutral is prohibited for (1) new branch-circuit installations after 

1996, (2) mobile homes, (3) recreational vehicles, and (4) areas  

where local codes prohibit grounding through the neutral 

conductors.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL Listed 30 A power supply cord, rated 120/240 V 

minimum. The cord should be type SRD or SRDT and  

be at least 4 ft. (1.22 m) long. The wires that connect to  

the dryer must end in ring terminals or spade terminals  

with upturned ends.

 

A UL Listed strain relief.

Summary of Contents for HYBRIDCARE YWHD560CHW0

Page 1: ...utillage et pièces 22 EXIGENCES D EMPLACEMENT 23 SYSTÈME DE VIDANGE 24 SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À L ALIMENTATION ÉLECTRIQUE CANADA SEULEMENT 25 INSTALLATION DES PIEDS DE NIVELLEMENT 26 CONNEXION DU TUYAU DE SORTIE 26 RÉGLAGE DE L APLOMB DE LA SÉCHEUSE 27 ACHEVER L INSTALLATION LISTE DE VÉRIFICATION 28 INVERSION DE LA PORTE FACULTATIF 28 DÉPANNAGE COUVERTURE ARRIÈRE INSTALLATION NOTES Date ...

Page 2: ...AFETY Certain internal parts are intentionally not grounded and may present a risk of electric shock only during servicing Service Personnel Do not contact the thermostat bracket while the appliance is energized ...

Page 3: ...t use leveling legs supplied with dryer if installing with a pedestal or a stack kit If using a power supply cord Use a UL Listed power supply cord kit marked for use with clothes dryers The kit should contain A UL Listed 30 A power supply cord rated 120 240 V minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals...

Page 4: ...llation place dryer at least 18 460 mm above floor If using a pedestal you will need 18 460 mm to bottom of dryer The dryer must not be installed or stored in an area where it will be exposed to water and or weather IMPORTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 40 F 4 C Lower temperatures may cause dryer to not shut off at end of...

Page 5: ... HUD Part 280 or Standard CAN CSA Z240 MH 18 min 457 mm 1 25 mm 5 127 mm 24 in 2 min 155 cm2 48 in 2 min 310 cm2 3 76 mm 3 76 mm 1 25 mm NOTE 0 0 mm spacing is allowed behind dryer providing drain hose is not kinked or pinched DRAIN SYSTEM Minimum diameter for a standpipe drain 2 51 mm Minimum carry away capacity 17 gal 64 L per minute A 1 4 6 mm diameter to 1 25 mm diameter Standpipe Adapter Kit ...

Page 6: ...at least 4 ft 1 22 m long must have four 10 gauge copper wires and match a 4 wire receptacle of NEMA Type 14 30R The ground wire ground conductor may be either green or bare The neutral conductor must be identified by a white cover Then choose a 3 wire power supply cord with ring or spade terminals and UL Listed strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have three 1...

Page 7: ...ING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician To supply the required 4 w...

Page 8: ...dryer until it is close to its final location ELECTRICAL INSTALLATION U S A ONLY Remove hold down screw and terminal block cover 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to Power Supply Cord Connection 3 wire direct connection Go to Direct Wire Connection 4 wire direct connection Go to Direct Wire Connection Power supply cord 3 wire receptacle NEM...

Page 9: ... for mobile homes and where local codes do not permit the use of 3 wire connections 4 wire receptacle NEMA type 14 30R 4 prong plug Spade terminals with upturned ends Ring terminals 2 Attach power supply cord to strain relief Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fi...

Page 10: ...e F green or bare of power supply cord under green external ground conductor screw A Tighten screw 3 wire receptacle NEMA type 10 30R 3 prong plug Spade terminals with upturned ends Ring terminals 4 Connect remaining wires 1 Remove center screw B Connect remaining wires under outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secur...

Page 11: ...strain relief UL marking on strain relief Put the threaded section of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads and tighten securely Fire Hazard Use 10 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections Co...

Page 12: ...27 mm Cut 11 2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 3 wire direct connection Go to 3 Wire Direct Wire Connection 4 wire direct connection Go to 4 Wire Direct Wire Connection If your wiring looks like this 4 Connect ground wire F A Connect ground wire green or bare F of direct wire cable under green external ground conductor screw A Tighten screw...

Page 13: ... ground conductor to neutral wire 3 Connect neutral wire C B Place hooked end of neutral wire white or center C of direct wire cable under center terminal block screw B hook facing right Squeeze hooked end together Tighten screw 4 Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tigh...

Page 14: ...anel Secure cover with hold down screw Now go to Connect Outlet Hose 4 Connect external ground wire G A CONNECT OUTLET HOSE 1 Attach hose Attach the goose neck fitting of the provided 6 ft 1 82 m drain hose to the drain valve at the bottom of dryer back panel Screw on coupling by hand until it is seated on valve connector 2 Tighten coupling Using channel locks tighten the coupling an additional tw...

Page 15: ... dryer is greater than 1 25 mm water could run out from front of filter 2 Adjust leveling legs If dryer is not level prop up using a wood block use a wrench to adjust legs up or down and check again for levelness Once dryer is level make sure all four legs are snug against the floor and dryer does not rock 3 Plug into a grounded 3 prong outlet 4 Check for leaks While running the first cycle check ...

Page 16: ...art check the following Controls are set to a running or On position Start button has been pressed firmly Dryer is plugged into an outlet and or electrical supply Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer automatically runs an installation diagnostic routine at the start of its first cycle NOTE You may notice an odor when dryer is first h...

Page 17: ...r peel the film from the dryer door before proceeding Using a T25 screwdriver remove the four screws securing the door hinge to the dryer and lift the door up and out to remove Place the door on a soft towel or other non scratch surface ALL DOORS 4 Remove inner door from outer door Position the door with the inside of the door facing up Using a Phillips screwdriver remove the 10 screws securing th...

Page 18: ... is at the bottom Using a T25 screwdriver remove the four screws securing the latch plate in place 8 Reinstall hinge assembly on opposite side Flip over the inner door to the left Using a T20 screwdriver reinstall the hinge assembly on the opposite side from which it was removed DOORS WITH LCD SCREEN 9 Remove rotating assembly Lift off inner door assembly Using a Phillips screwdriver remove the tw...

Page 19: ...f rotating assembly see Step 12 Press tubing into indents 12 Reinstall inner door assembly Position the door with the inside of the door facing up Using a Phillips screwdriver reinstall the 10 screws removed earlier securing the inner door to the outer door 13 Reinstall door on dryer Doors with electrical wiring Pull the wire through the front panel opening before reinstalling the door Insert the ...

Page 20: ...ur website and reference Frequently Asked Questions to possibly avoid the cost of a service call 14 Reconnect wiring Plug in wire Using a Phillips screwdriver secure the rotating assembly to the hinge with the screw removed earlier DOORS WITH LCD SCREEN 6 18 ...

Reviews: