COMPONENT ACCESS (Cont.)
Low Profile Microwave Hood Combination
n
4-7
†®Torx is a registered trademark of Acument Intellectual Properties, LLC.
Hood Motor location
1.
The hood motor is located on the left side of the unit and can
be serviced by removing the outer wrapper.
Interlock Switch Replacement
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
1.
Remove two Torx
†
screws on the right front of cavity. Open
the door to access these.
2.
The control panel must be removed to access the switches
after these Torx screws are removed.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.