- 27 -
User Menu B14-B21
B14 year
In this function, you set the year.
1.
Press the key next to the temperature display (digit flashes).
2.
Turn the switch to the desired setting.
3.
Press the key next to the temperature display (digit stops flashing).
You set the year from 6 to 20.
B15 CombiWash
In this function, you activate or deactivate CombiWash.
0=
Manual
cleaning
1=
CombiWash
Press step key to change setting.
B16 Pulsing interval, reheating
In this function, you set the pulsing time in the reheating mode.
1.
Press the key next to the temperature display (digit flashes).
2.
Turn the switch to the desired time.
3.
Press the key next to the temperature display (digit stops flashing)
You set the time from 5 – 50 sec.
B17 Pulsing interval, Combi Steam 1
In this function, you set the pulsing time for Combi Steam 1.
1.
Press the key next to the temperature display (digit flashes).
2.
Turn the switch to the desired time.
3.
Press the key next to the temperature display (digit stops flashing)
You set the time from 2 to 50 sec.
B18 Pulsing interval, Combi Steam 2
In this function, you adjust the pulsing time for Combi Steam 2.
1.
Press the key next to the temperature display (digit flashes).
2.
Turn the switch to the desired time.
3.
Press the key next to the temperature display (digit stops flashing)
You set the time from 1 sec. to the number of seconds specified to be the pulsing time for
Combi Steam 1.
B19 Save all (Backup)
In this function, you save set-up and programs to the IO board for subsequent restoration.
This can be used as backup when set-up and programs are correct.
Press alarm key to save.
B20 Restore all
In this function, you restore set-up and programs you have saved earlier.
B21 Restore original
In this function, you restore the original programs from 0 to 4.
1.
Press step key to select program.
2.