450364 - 1
L.P. Gas Conversion Instructions
Disconnect electrical power to the dryer.
IMPORTANT:
The following procedures must be performed on both top and bottom tumblers.
Open the panels located just below each loading door.
Close all shutoff valves (for both top and bottom tumbler) in dryer’s gas supply line.
Follow procedure for “Removing Burner Tube Assembly.”
Using a 3/8” wrench or socket, remove the existing orifice and replace it with an orifice from the kit.
IMPORTANT:
Use extreme care when removing and replacing orifice (injector). This orifice (injector) is made of
brass, which is easily damaged.
Use a flat screwdriver to remove the regulator vent cap.
•
For unregulated L.P. gas (most countries):
install blocking pin (P/N 140414).
Reinstall the burner tube into the burner tube receiver bracket.
Connect the union and electrical plug.
Repeat these steps for the other burner.
Affix L.P. Conversion Label (P/N 114515) to the dryer’s data label.
Complete L.P. Kit Conversion Confirmation Label (P/N 114083) and affix this label as close as possible to the dryer’s
existing dryer rating (data) label/plate.
Regulate (govern) gas externally (refer to “To Test and Adjust Gas Pressure” in chart on page
17) to the correct gas
pressure for the gas being used. Operate dryer through one complete cycle to ensure proper operation.
Affix L.P. Conversion Rating Label Addendum (P/N 114090) as close as possible to the dryer’s existing dryer rating
(data) label/plate.
IMPORTANT:
Never test for leaks with an open flame!!! Use a soapy water solution or product intended for that