450364 - 1
Maytag Co.
19
To Replace Lint Compartment / Exhaust Hi-Limit (190° F [87° C]) Thermostat
This thermostat is part of the “lint box assembly” and is secured to the top lint box beneath tumbler. As a safety
device, this thermostat will open (shut off) the heating unit circuit if an excessive temperature occurs. The dryer
motors will remain on, even if the thermostat is open.
IMPORTANT:
Under no circumstances should heat safety devices be disabled.
1.
Discontinue electrical power to the
dryer.
2.
Remove control or lint panel.
3.
Locate exhaust hi-limit at front left side
of lint box. Remove wires from
thermostat and remove the two 11/32”
Hex nuts.
4.
Reverse this procedure for installing
a hi-limit thermostat.
5.
Reestablish electrical power to the
dryer.
D. SAIL SWITCH ASSEMBLY
C. THERMOSTATS
To Replace Burner Hi-Limit Thermostat
This thermostat is an important safety device serving as an added protection against failure of the airflow (sail switch)
to open in the event of motor failure or reduced airflow condition.
IMPORTANT:
Under no circumstances should heat circuit safety devices ever be disabled.
1.
Discontinue electrical power to the dryer.
2.
Remove back guard.
3.
Disconnect wires from hi-limit thermostat.
4.
Remove screws securing thermostat
to the heat duct. Remove thermostat.
5.
Reverse procedure for installing new
thermostat.
6.
Reestablish electrical power to the
dryer.
Summary of Contents for MAYTAG MLG-52