Removing Blower Motor
1.
Discontinue electrical power to the dryer.
2.
Remove back guard.
3.
Disconnect the harness from blower motor.
4.
Disconnect and remove relay panel assembly.
5.
Remove four nuts holding blower motor mount to blower housing.
6.
Pull out blower motor mount.
7.
Remove nuts holding fan to motor and remove fan.
8.
Unbolt motor from mount and remove.
9.
Reverse procedure for installation.