450364 - 1
Maytag Co.
27
FEATURE
SYMBOL
FEATURE
TEXT
FEATURE
FEATURE
INFORMATION
EXH
EXHAUST
TEMP PROBE
Exhaust
Temperature Probe
(in Deg. F or C)
AXL
AXIAL TEMP PROBE
Axial Thermistor Probe
(in Deg. F or C)
RPM
TUMBLER
ROTATION SPEED
Tumbler Speed in
Revolutions Per Minute
R.P.M.
MIN
TIME REMAINING
Time remaining
in the diag. cycle
0 to 99
(in minutes)
CODE
HELP CODE MENU
Help Menu Code
Help Codes
T1
THERMOSTAT
BURNER 1
Thermostat
(Heat Output Burner 1)
ON - OFF
T2*
THERMOSTAT
BURNER 2
Thermostat
(Heat Output Burner 2)
ON - OFF
H1
HEAT RETURN
BURNER 1
Heat Return Burner 1
ON - OFF
H2*
HEAT RETURN
BURNER 2
Heat Return Burner 2
ON - OFF
C1
HEAT RELAY 1
CONTACTS
Heat relay 1 contacts
OPEN - CLOSED
C2*
HEAT RELAY 2
CONTACTS
Heat relay 2 contacts
OPEN - CLOSED
B
BLOWER
Fan output
ON - OFF
F
FORWARD
Forward drive output
ON - OFF
R
REVERSE
Shows reversing
relay is on
ON - OFF
D
DOOR
Main Door
OPEN - CLOSED
L
LINT
Lint Door
OPEN - CLOSED
P
WATER PRESSURE
H
2
O Input
ON - OFF
S
SAIL SWITCH
Sail Switch
OPEN - CLOSED
V
VAULT SWITCH
Vault Switch
OPEN - CLOSED
W
WATER OUTPUT
S.A.F.E. output
ON - OFF
3: HELP MENU
The help menu allows the user to view the status of different parts of the dryer. When a feature is highlighted, the
center section will list that feature and its current status. The items in the help menu will refer to the current running
cycle that was selected in Diagnostic Mode.
Pressing the HI/UP ARROW key will allow the user to move the highlighted bar around the help menu screen. For
example, highlighting “S” will show the status of the sail switch.
Pressing the STOP key will return the controls to Diagnostic Mode.
The table below shows the standard features available and the symbol they correlate with.
Summary of Contents for MAYTAG MLG-52
Page 34: ...Part No 450364 1 01 27 14 ...