24
Maytag Co.
450364 - 1
F. TO REPLACE LINT DRAWER SWITCH
1.
Discontinue electrical power to the dryer.
2.
Remove the two nuts holding the lint switch bracket in place.
3.
Remove lint switch cover and disconnect the two terminals of the switch.
4.
Remove switch by pressing tabs together and push switch out.
5.
Install new switch by reversing procedure.
3: Diagnostic Mode
1: FAULT RECORDING
1: UPPER DRYER FAULTS*
When a fault is recorded on the top pocket, it can be viewed in this location. If no fault(s) have been recorded, then
“NO UPPER FAULTS”
will be displayed.
1: (Description of fault)
2: (Description of fault)
3: (Description of fault)
4: (Description of fault)
5: (Description of fault)
2: LOWER DRYER FAULTS*
When a fault is recorded on the bottom pocket, it can be viewed in this location. If no fault(s) has been recorded, then
“NO LOWER FAULTS”
will be displayed.
1: (Description of fault)
2: (Description of fault)
3: (Description of fault)
4: (Description of fault)
5: (Description of fault)
* Single units will only have one set of faults.
3: EVENTS
E1:XX
E2:XX
E3:XX
E4:XX
E5:XX
E6:XX
E7:XX
E8:XX
E9:XX
EA:XX
EB:XX
EC:XX
ED:XX
RESET
This will reset all of the event counts to 0.
All CODES starting with an “E” represent an event. An event failure is one that would still allow the dryer to run in a
safe condition. The number after the “E” code indicates the amount of times that event failure occurred. The 13
Event Code failures are listed in the following table.
Summary of Contents for MAYTAG MLG-52