11
Connect remaining wires
4.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements".
C
B
Place hooked end of neutral wire (white
or center) (C) of direct wire cable under
center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
3.
Connect neutral wire
1.
Prepare to connect neutral
ground wire and neutral wire
B
E
A
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
oPTIonAl 3-WIRE ConnECTIon
You must verify with a qualified electrician that this grounding
method is acceptable before connecting.
C
B
E
Connect neutral ground wire
and neutral wire
2.
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements".