Prepare to connect neutral
ground wire and neutral wire
A
E
B
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
B
C
E
Connect neutral ground wire
and neutral wire
2.
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to Venting
Requirements.
Optional 3-wire Connection
You must verify with a qualified electrician that this
grounding method is acceptable before connecting.
Connect remaining wires
7.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold-
down screw. Now, go to Venting Requirements.
C
B
Place hooked end of neutral wire (white or center) (C) of direct
wire cable under center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
6.
Connect neutral wire