5-7
REMOVING THE ELECTRONIC CONTROL BOARD
NOTE:
Sharp edges may be present.
1.
Unplug the clothes vitalizer or disconnect
the power.
2.
Remove the twelve T-15 Torx screws from
the top component cover and remove the
cover from the unit (see page 5-2).
The component described on this page is
shown below.
4.
Remove the rubber band from the locking
arms of the electronic control board hold-
ers.
5.
Push the two locking arms outward and
slide the electronic control board out of the
holders, then place a piece of heavy paper
or cardboard under the board, and set it on
top.
6.
Disconnect the four wire connectors from
the electronic control board pins.
Rubber Band
Locking Arm
Locking Arm
REASSEMBLY NOTE: The ribbon cable con-
nectors are polarized with a tab so that they
cannot be reversed. Slide the cable connector
tab into the board connector slot when rein-
stalling the cables.
4 Wire Connectors
3.
Pull the two ribbon cables out of the con-
nectors.
2 Ribbon Cables
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
WARNING
Electronic Control Board