6-1
COMPONENT TESTING
Before servicing, check the following:
• Make sure that the power cord is firmly
plugged into a live circuit with the proper
voltage.
• Check for a blown household fuse or circuit
breaker that has tripped.
• Check the connections before replacing a
component. Look for broken or loose wires,
failed terminals, or wires that are not pressed
into their connectors far enough.
• Check for wire connectors that are not
pressed tightly onto their terminals.
• Resistance tests must be made with the
power cord unplugged from the outlet, and
with the wiring disconnected.
• All tests should be made with a VOM (volt-
ohmmeter) or DVM (digital voltmeter) hav-
ing a sensitivity of 20,000 ohms-per-volt DC
or greater.
COMPRESSOR
Refer to page 5-3 for the procedure for servic-
ing the compressor.
1. Unplug the clothes vitalizer or disconnect
the power.
2. Set the ohmmeter to the R x 1 scale.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.
3. Disconnect the compressor’s 2-wire con-
nector from the wiring harness.
4. Touch the ohmmeter test leads to the con-
nector pins coming from the compressor.
The meter should indicate approximately
8 to 15
Ω
.
5. Disconnect the compressor wires from the
capacitor terminals.
6. Touch the ohmmeter test leads to the
orange and black compressor wire termi-
nals. The meter should indicate approxi-
mately 40 to 80
Ω
.