7-2
Keypad Test
Press the following keypads and check the op-
eration of their corresponding LED:
a) Heavy Duty Cotton Poly
b) RegularCare Cotton Poly
c) Wool
d) Delicate
e) QuickCare
f) Dry
g) Buzzer
h) Start/Cancel
i) Up (
∆
) and down (
∇
) arrows. Since nei-
ther of these keypads has its own LED,
pressing either of them will turn on an
LED in the time bar, advancing them
each time the keypad is pressed.
j) Press the “up (
∆
) arrow” twice to move
to the next test, or press the Start/Can-
cel keypad to exit the “Service Diag-
nostic Test,” and return to the normal
“idle” state.
Door Switch & Buzzer Test
To test the door switch & buzzer:
a) Open one of the cabinet doors so that
the door switch closes (button is out).
Several of the Time LEDs should light.
b) Press one of the keypads with the door
open, and the buzzer should sound.
NOTE: This test can also be used to
audibly check for a defective keypad. If
a keypad is pressed with the door open
and the buzzer does not sound, the
keypad is defective.
c) Close the cabinet doors and the Time
LEDs should turn off.
d) Press the “up (
∆
) arrow” twice to move
to the next test, or press the Start/Can-
cel keypad to exit the “Service Diag-
nostic Test,” and return to the normal
“idle” state.
Thermistor Test
During the test, readings are continuously
taken from the thermistor, and the results will
be displayed as follows:
a) The “30” LED in the Time Bar will turn
on to indicate that the test is in progress.
b) If the thermistor is okay, all other LEDs
will be turned off.
c) If the thermistor is “open”, or if its con-
nectors are loose, the “Drying” LED will
flash.
d) If the thermistor is “shorted,” the “Mist-
ing” LED will flash.
e) Press the “up (
∆
) arrow” twice to move
to the next test, or press the Start/Can-
cel keypad to exit the “Service Diag-
nostic Test,” and return to the normal
“idle” state.
Compressor Test
The compressor will turn on during this test
and the results will be displayed as follows:
a) The “25” LED in the Time Bar will turn
on to indicate that the test is in progress.
All the other LEDs should remain off.
b) Press the “up (
∆
) arrow” twice to move
to the next test, or press the Start/Can-
cel keypad to exit the “Service Diag-
nostic Test,” and return to the normal
“idle” state.
Fan Test
The fan will turn on during this test and the
results will be displayed as follows:
a) The “20” LED in the Time Bar will turn
on to indicate that the test is in progress.
All the other LEDs should remain off.
b) Press the “up (
∆
) arrow” twice to move
to the next test, or press the Start/Can-
cel keypad to exit the “Service Diag-
nostic Test,” and return to the normal
“idle” state.
Summary of Contents for Personal Valet PVBN600
Page 16: ...2 6 NOTES ...
Page 22: ...3 6 NOTES ...
Page 54: ...8 2 NOTES ...
Page 56: ...CORPORATION ...