4-12
OVEN TEMPERATURE CALIBRATION
Model RF315PXE
• Once you reach the desired temperature
offset, there is a 5-second pause before the
LED display prompt START? begins flash-
ing. Press the START/ENTER keypad to
activate the new temperature adjustment.
• If the START/ENTER pad is not pressed
within 1-minute after the START? prompt
appears, the adjustment is ignored, and the
display reverts to idle.
• The BAKE temperature adjustment cannot
result in operating temperatures higher than
500
°
F, or lower than 170
°
F, as measured at
the center of the oven cavity.
• Once the BAKE temperature has been ad-
justed, the BROIL temperatures are auto-
matically offset by the same degree.
• If power is interrupted, any previous tem-
perature adjustment will revert back to the
default setting of 00.
DIAGNOSTICS
1.
All diagnoses of this range must begin
with a normal check of the line voltage,
blown fuses, and defective components.
2.
All units that are defective the first few
days of use should be checked for loose,
or miswired connections.
3.
All checks should be made with a meter
that has a sensitivity of 20,000 ohms-per-
volt, or greater.
TEMPERATURE ADJUSTMENT
• Press and hold the BAKE keypad for
5-seconds. The current offset, if any, is
shown in the 3-digit display.
• Pressing the TEMP keypad up arrow
s
adjusts the temperature in 10
°
F increments
in the following sequence: 0
°
; 10
°
; 20
°
; 30
°
;
-30
°
; -20
°
; -10
°
; 0
°
; and so on.
Summary of Contents for RF302BXE
Page 26: ...2 6 NOTES ...
Page 68: ...4 16 NOTES ...