Page 1: ...cabinets or wall i WIRING KNOCKOUT Figure 1 2 Cut holes to acconodate ventilating duct allowing 4 clearance on all 4 sides for back vent Allow clearance toward front for vertical vent Allow on other 3 sides for top vent 3 Cut appropriate hole for electrical wiring 4 Run wire through wall or cabinets according to National ElectrIcal Code and applicable local codes DO NOT turn power on until install...

Page 2: ...electrical wire through knockout 13 Tighten screws to secure hood Be sure screw head is in narrow neck of keyhole slot 14 Install proper duct work 15 Complete electrical wiring In junction box according to the national Electrical Code and applicable Local Codes NOTE This unit must be permanently grounded in accordance with the National Electrical Codeand applicable Local Codes 16 Replace junction ...

Page 3: ...2 From the blower positron shown in Figure 7 lift the Blower Assembly vertically into mounting position 3 The 3 blower discharge surface should now be flush agatnst top of hood This will allow proner air flow from the blower through the top vent The wider 5 surface will be to the rear Figure 7 VERTICAL DISCHARGE HORIZONTAL DISCHARGE VENT REAR OF HOOD THIS SURFACE TO TOP HORIZONTAL DISCHARGE 1 Figu...

Page 4: ...n 3 To avoid providing fuel for a grease pan fire clean lint and grease from all hood surfaces interior and exterior Be sure to remove and clean air filter every three months 4 Do not saturate electrical connections switches and motor in water during cleaning Remember WATER AND ELECTRICITY DO NOT MIX 5 If any electrical malfunction becomes evident during use disconnect power to hood at your home f...