17
Select the best location
Location for Installing the Indoor Unit
Where there is no obstacle near the air outlet and air can easily be blown
to every corner.
Where piping and wall hole can easily be arranged.
Observe the required distance from ceiling and wall according to the
wiring diagram.
Where the air filter can easily be removed.
Keep the unit and remote control 1 m or more from the television, radio
etc.
To prevent the effects of a fluorescent lamp, keep the unit as far as
possible.
Do not put anything near the air inlet that could obstruct it.
In a place that can bear the weight and will not increase operating noise
and vibrations.
Location for Installing the Outdoor Unit
Install in a convenient and well-ventilated place; avoid installing it where
flammable gas could leak.
Observe the required distance from the wall.
Do not install the outdoor unit in a dirty or greasy place, near a
vulcanization gas exit or highly salty seashore.
Avoid installing it at the roadside where it could be soiled with muddy
water.
A fixed base where operating noise will not increase.
Where the air outlet is not obstructed.
Outdoor unit installation
1.
Install Drain Port and Drain Hose (for heat-pump model
only)
The condensate drains from the outdoor unit when the unit operates in
heating mode. In order not to disturb your neighbours and protect the
environment, install a drain port and a drain hose to direct the
condensate water. Just install the drain port and rubber washer on the
chassis of the outdoor unit, then connect a drain hose to the port as
shown in the figure on the right.
2. Install and Fix Outdoor Unit
Fix with bolts and nuts tightly on a flat and strong floor. If installed on
the wall or roof, make sure to fix the support well to prevent it from
shaking due to serious vibrations or strong wind.
3. Outdoor Unit Piping Connection
Remove the valve caps from the 2-way and 3-way valve. Connect the
pipes to the 2-way and 3-way valves separately according to the
required torque.
4. Outdoor Unit Cable Connection (see page 21)
Indoor unit
He
ight
sho
u
ld
be
less than 5
m
Pipe length
max 15 m
Outdoor unit
H
e
igh
t sh
ou
ld
be less than 5
m
Indoor unit
Pipe length
max 15 m
Outdoor
unit
Drain port
Drain hose
(prepare by user)
Washer
33933049GB.fm Page 17 Monday, January 10, 2005 5:27 PM