5-8
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
MAGNETRON
Refer to page 4-27 for the procedure for ac-
cessing the magnetron.
1. Unplug microwave oven or disconnect
power.
2. Disconnect one of the wires from the
magnetron filament terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the
filament terminals. The meter should in-
dicate less than 1 Ω.
Filament
Terminals
WAVEGUIDE THERMOSTAT
Refer to page 4-29 for the procedure for ac-
cessing the waveguide thermostat.
1. Unplug microwave oven or disconnect
power.
2. Disconnect one of the wires from the
thermostat connectors.
3. Set the ohmmeter to the R x 100K scale.
4. Touch the ohmmeter test leads to the
thermostat connector pins. The meter
should indicate a closed (0
Ω)
circuit.