- 12 -
Installation instruction
Installation diagram
Distance from wall
should be over 50mm
Indoor unit
Outdoor unit
Distance from ceiling
should be over 200mm
Distance from the wall
should be over 50mm
Distance from floor
should be over 2500mm
Air intake distance from
the wall should be over
250mm
Air intake distance from
the wall should be over
250mm
Air outlet distanc
e fr
om the
wall should be o
ver 500mm
Over 250mm
NOTE:
The figure is only a simple presentation of the
unit, it may not match the external appearance of the
product you purchased. Installation must be performed
in accordance with the national wiring standard by
authurized service people only.
To get detail installation information, please go to:
docs.whirlpool.eu
Distance from the wall
should be over 50mm
When install interconnection cord, make sure that the color of wires and the terminal No. of outdoor unit shall be
same as those in indoor unit.
Cable Specifications
Capacity (Btu/h)
Power cord
Power connecting cord
Type
Normal cross -
sectional area
Type
Normal cross -
sectional area
7K, 9K, 12K
H07RN-F
1.0mm
2
X3
H07RN-F
1.0mm
2
X5
18K
H07RN-F
1.5mm
2
X3
H07RN-F
1.5mm
2
X5
24 K
H07RN-F
2.5mm
2
X3
H07RN-F
2.5mm
2
X5