4. Connecting the Cable
•
Indoor Unit
1) Open the front panel, remove the covering
plate by loosening the screw.
2) Connect the power connecting cord to the
indoor unit by connecting the wires to the
terminals on the control board individually
according to wiring diagram.
3) Secure the power connecting cord on the
control board with cable clamp.
4) Refit the covering plate and tighten the screw.
NOTE:
(depending on the model) It is necessary
to remove the cabinet to perform connections
with the indoor unit terminal.
• Outdoor Unit
1) Remove the access door from the unit by
loosening the screw. Connect the wires to
the terminals on the control board
individually in accordance with the indoor unit
connection.
2) Secure the power connecting cord on the
control board with cable clamp.
3) Refit the access door in the original position
and tighten the screw.
4) Use a recognized circuit breaker for 24K
model between the power source and the
unit. A disconnecting device to adequately
disconnect all supply lines must be fitted.
Covering plate
Front panel
Indoor unit
Outdoor unit
Terminal (inside)
Cabinet
Power Connection
Cable
25
Access door
Terminal
(inside)
Type
Capacity
(Btu/h)
Power cord
Power connecting cable
Main power
supply (Note)
On/Off
7k
H05VV-F, 3G x 1.0 mm
2
H05RN-F, 3G 1.0 mm
2
;
H05RN-F, 2G 0.75 mm
2
To indoor
9k
H05VV-F, 3G x 1.0 mm
2
H05RN-F, 3G 1.0 mm
2
;
H05RN-F, 2G 0.75 mm
2
To indoor
12k
H05VV-F, 3G x 1.0 mm
2
H05RN-F, 3G 1.0 mm
2
;
H05RN-F, 2G 0.75 mm
2
To indoor
18k
H05VV-F, 3G x 1.5 mm
2
H07RN-F, 3G 1.5 mm
2
;
H05RN-F, 2G 0.75 mm
2
To indoor
CAUTION:
1. Make sure that the colour of wires and the terminal number of the outdoor unit are the same as those
of the indoor unit.
2. Use an individual power circuit specifically for the air conditioner. As for the wiring method, refer to the
circuit diagram on the appliance.
3. Check that the cable specification conforms to the table as follows.
4. Check the wires and make sure that they are all tightly fastened after cable connection. The cable
should be tighly fastened by cable clamp.
5. Be sure to install an earth leakage circuit breaker in a wet or moist area.
Cable Specifications