background image

WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati 

Components

Overview components Mistral I270

Summary of Contents for UI MISTRAL

Page 1: ...TION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati WhirlpoolCorp WhatMatters Golden Service Technical Training 2017 Induction hob UI MISTRAL for I200 I270 ...

Page 2: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Induction UI Mistral for I200 and I270 UI Mistral I270 I200 ...

Page 3: ... Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Installation Operation Components Repair guide line Troubleshooting Marketing information Chapter List Induction UI Mistral for I200 and I270 UI Mistral ...

Page 4: ...FIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Installation Dimensions 65 cm Dimensions 77 cm Standard Installation Full integrated installation Electrical connection ...

Page 5: ...and Nicola Bargagnati Installation Dimensions 65 cm version Induction I 200 Worktop thickness min 30mm Idem for 650 mm 0 560 2 mm R Min 6 5 mm Max 8mm Min 480mm Max 492mm 0 560 2 mm R Min 11 5 mm Min 50mm Min 480mm Max 492mm 6mm 593 0 mm 2 0 513 2 mm R Min 6 5mm Max 8mm R 11 5mm 4 mm 553mm 510mm 476mm 590mm 53mm ...

Page 6: ...and Nicola Bargagnati Installation Dimensions 65 cm version Induction I 200 Worktop thickness min 30mm Idem for 650 mm 0 560 2 mm Min 50mm Min 480mm Max 492mm 560 0 mm 2 6mm 0 653 2 mm 0 513 2 mm R Min 6 5 mm Max 8mm R Min 11 5 mm R Min 6 5mm Max 8mm R 11 5mm Min 480mm Max 492mm 4 mm 553mm 510mm 476mm 650mm 53mm ...

Page 7: ... Padula and Nicola Bargagnati Installation Dimensions 77 cm version Induction I 200 Worktop thickness min 30mm 0 750 2 mm Min 50mm Min 480mm Max 492mm 750 0 mm 2 6mm 0 773 2 mm 0 513 2 mm R Min 6 5 mm Max 8mm R Min 11 5 mm R Min 6 5mm Max 8mm R 11 5mm Min 480mm Max 492mm 4 mm 743mm 510mm 476mm 770mm 53mm ...

Page 8: ...TION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Installation Standard Installation Induction I 200 Distance X is specified in the hood s documentation ...

Page 9: ...y Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Induction I 200 15mm 100mm 65mm min 45mm min 550mm min 5mm min 5mm min 20mm 60mm min 20mm 60mm min 20mm min 45mm min 550mm min 20mm Installation Standard Installation ...

Page 10: ...HIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Induction I 200 Installation Standard Installation 2 1 2mm x4 x4 3 90 C ...

Page 11: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Induction I 200 Installation Standard Installation 2 1 x4 ...

Page 12: ...cola Bargagnati 11 5 6 0 5 Perimetral Gasket Silicon COOKTOP CUT OUT DIM mm Depth Length Width Length Width 590 Vetroceramic Cooktops Flush Installation 53 590 510 593 560 513 480 492 0 2 770 Vetroceramic Cooktops Flush Installation 53 770 510 773 750 513 480 492 0 2 Induction I 200 Installation Standard Installation ...

Page 13: ...ws which have the screw head on the outside This is important they are not reachable after installation Put in 6 screws with the bigger head from inside of the frame These ones can be loosen easier when the hob is installed The glass frame will stay in the worktop but the metal support with the electronic can be removed by loosing these screws On the back side there are 2 hooks no screws Induction...

Page 14: ...a Padula and Nicola Bargagnati Installation Electrical connection I270 A main cable is delivered with the cooktop not fitted in the factory for I270 On house side L1 and L2 are not clamped together N1 and N2 are not clamped together You have to clamp in order to allow using the cooktop with 1 phase 230V ...

Page 15: ... is delivered with the cooktop On house side L1 and L2 are clamped together in one cable end N1 and N2 are clamped together in one cable end In order to allow using the cooktop with 1 phase 230V If the cooktop will be connected with 2 phase the life connection L1 L2 have to be cutted and connected one by one Installation Electrical connection hob ...

Page 16: ...ty Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati R black S brown T blue gray E yellow N blue 220 240V 220 240V AU UK IRL 220 240V3 BE 230V 2 Phase 2N NL 380 415V3N 380 415V2N Installation Electrical connection hob ...

Page 17: ...hnical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Exploded view Overview components Overview converter board ESAM connection Overview cable connection Induction coil power level NTC User Interface Mistral Cooling fan ...

Page 18: ...Nicola Padula and Nicola Bargagnati Components Exploded view Mistral I200 Induction zones Hob glas surface incluse frame Fan Fixation clamps Inox frame Touch control Mistral Connection cable IPC UI IPC power board I200 incluse Housing and Fan Filter Board Filter Board Metal Housing Plastic Housing ...

Page 19: ...d Nicola Bargagnati Induction zones Hob glas surface incluse frame Fan Fixation clamps Inox frame Touch control Mistral Connection cable IPC UI Cover Electrical connection Filter Board Metal Housing Plastic Housing Induction zones IPC power board Fuse Fan Cable IPC power board Components Exploded view Mistral I200 ...

Page 20: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview components Mistral I270 ...

Page 21: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview components Mistral I270 ...

Page 22: ...ONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Input VN 230 Volts AC 10 Vmin 207 VAC Vmax 253 VAC fq 50 60 Hz 2Hz Components Overview converter board Mistral I270 ...

Page 23: ...ONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Input VN 230 Volts AC VAC Vmin 196VAC Vmax 263 VAC fq 50 60 Hz 2Hz Components Overview converter board Mistral I270 ...

Page 24: ...Nicola Bargagnati For Mistral UI if we have IPC I200 it will be possible to connect e SAM and download the setting file if it will be available I200 converter board is prepared for ESAM usage via 7 pin connector E SAM cable has to be linked in pos J34 Components Converter board e SAM connection only for Mistral I200 ...

Page 25: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview cable connections I270 ...

Page 26: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview cable connections I200 ...

Page 27: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview cable connections I200 an example ...

Page 28: ...HIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview cable connections Mistral i270 Round coils example ...

Page 29: ...HIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview cable connections Mistral i270 Round dual zone coil ...

Page 30: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Overview cable connections Mistral i270 Oval coils ...

Page 31: ...500 200 i270 260 260x260 Double ring 16 2300 200 i270 260 260x260 Double ring 15 2100 200 i270 260 260x260 Double ring 14 1900 200 i270 260 260x260 Double ring 13 1700 200 i270 260 260x260 Double ring 12 1500 200 i270 260 260x260 Double ring 11 1300 200 i270 260 260x260 Double ring 10 1100 200 i270 260 260x260 Double ring 9 900 100 i270 260 260x260 Double ring 8 800 100 i270 260 260x260 Double rin...

Page 32: ... i270 double 18 1750 300 i270 OVI i270 double 17 1600 150 i270 OVI i270 double 16 1450 150 i270 OVI i270 double 15 1300 150 i270 OVI i270 double 14 1150 150 i270 OVI i270 double 13 1000 100 i270 OVI i270 double 12 900 100 i270 OVI i270 double 11 800 100 i270 OVI i270 double 10 700 100 i270 OVI i270 double 9 600 100 MOKA 5 i270 OVI i270 double 8 500 100 i270 OVI i270 double 7 400 100 i270 OVI i270 ...

Page 33: ...1100 300 i270 OVI i270 single 18 875 150 i270 OVI i270 single 17 800 75 i270 OVI i270 single 16 725 75 i270 OVI i270 single 15 650 75 i270 OVI i270 single 14 575 75 i270 OVI i270 single 13 500 50 i270 OVI i270 single 12 450 50 i270 OVI i270 single 11 400 50 i270 OVI i270 single 10 350 50 i270 OVI i270 single 9 300 50 i270 OVI i270 single 8 250 50 i270 OVI i270 single 7 200 50 i270 OVI i270 single ...

Page 34: ...er Watt Delta between levels Watt Simmering Melting Gentle cook i270 240 260 Singel zone Booster 3000 700 i270 240 18 2300 200 i270 240 17 2100 100 i270 240 16 2000 150 i270 240 15 1850 200 i270 240 14 1650 200 i270 240 13 1450 150 i270 240 12 1300 100 i270 240 11 1200 150 i270 240 10 1050 150 i270 240 9 900 150 i270 240 8 750 150 i270 240 7 600 150 i270 240 6 450 100 X i270 240 5 350 100 i270 240...

Page 35: ...icon Power Watt Delta between levels Watt Simmering Melting Gentle cook i270 210 Booster 3000 700 i270 210 18 2300 200 i270 210 17 2100 100 i270 210 16 2000 150 i270 210 15 1850 200 i270 210 14 1650 200 i270 210 13 1450 150 i270 210 12 1300 100 i270 210 11 1200 150 i270 210 10 1050 150 i270 210 9 900 150 i270 210 8 750 150 i270 210 7 600 150 i270 210 6 450 100 X i270 210 5 350 100 i270 210 4 250 1...

Page 36: ... level icon Power Watt Delta between levels Watt Simmering Melting Gentle cook i270 145 Booster 1800 600 i270 145 18 1200 100 i270 145 17 1100 100 i270 145 16 1000 100 i270 145 15 900 100 i270 145 14 800 100 i270 145 13 700 100 i270 145 12 600 100 i270 145 11 500 50 i270 145 10 450 50 i270 145 9 400 50 i270 145 8 350 50 i270 145 7 300 50 i270 145 6 250 50 X i270 145 5 200 50 i270 145 4 150 50 X i2...

Page 37: ...ay level icon Power Watt Delta between levels Watt Simmering Melting Gentle cook i200 145 Booster 1800 400 i200 145 18 1400 100 i200 145 17 1300 100 i200 145 16 1200 100 i200 145 15 1100 100 i200 145 14 1000 100 i200 145 13 900 100 i200 145 12 800 100 i200 145 11 700 100 i200 145 10 600 100 i200 145 9 500 100 i200 145 8 400 100 i200 145 7 300 50 i200 145 6 250 50 i200 145 5 200 50 i200 145 4 150 5...

Page 38: ...ay level icon Power Watt Delta between levels Watt Simmering Melting Gentle cook i200 180 Booster 2500 600 i200 180 18 1900 200 i200 180 17 1700 150 i200 180 16 1550 150 i200 180 15 1400 200 i200 180 14 1200 200 i200 180 13 1000 150 i200 180 12 850 150 i200 180 11 700 100 i200 180 10 600 100 i200 180 9 500 100 i200 180 8 400 100 i200 180 7 300 50 i200 180 6 250 50 i200 180 5 200 50 i200 180 4 150 ...

Page 39: ...level icon Power Watt Delta between levels Watt Simmering Melting Gentle cook i200 210 Booster 3700 1300 i200 210 18 2400 300 i200 210 17 2100 200 i200 210 16 1900 200 i200 210 15 1700 200 i200 210 14 1500 200 i200 210 13 1300 200 i200 210 12 1100 200 i200 210 11 900 100 i200 210 10 800 100 i200 210 9 700 100 i200 210 8 600 100 i200 210 7 500 100 i200 210 6 400 100 i200 210 5 300 100 i200 210 4 20...

Page 40: ...200 OVI 5 single Booster 1850 650 i200 OVI 5 single 18 1200 100 i200 OVI 5 single 17 1100 100 i200 OVI 5 single 16 1000 100 i200 OVI 5 single 15 900 100 i200 OVI 5 single 14 800 100 i200 OVI 5 single 13 700 100 i200 OVI 5 single 12 600 100 i200 OVI 5 single 11 500 100 i200 OVI 5 single 10 400 50 i200 OVI 5 single 9 350 50 i200 OVI 5 single 8 300 50 i200 OVI 5 single 7 250 50 i200 OVI 5 single 6 20...

Page 41: ...200 OVI 3 single Booster 1850 650 i200 OVI 3 single 18 1200 100 i200 OVI 3 single 17 1100 100 i200 OVI 3 single 16 1000 100 i200 OVI 3 single 15 900 100 i200 OVI 3 single 14 800 100 i200 OVI 3 single 13 700 100 i200 OVI 3 single 12 600 100 i200 OVI 3 single 11 500 100 i200 OVI 3 single 10 400 50 i200 OVI 3 single 9 350 50 i200 OVI 3 single 8 300 50 i200 OVI 3 single 7 250 50 i200 OVI 3 single 6 20...

Page 42: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components NTC components for I200 ...

Page 43: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Zone NTC for I200 ...

Page 44: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components NTC components for I270 ...

Page 45: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components Zone NTC for I270 ...

Page 46: ...Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Components User Interface Mistral User Interface Touch sensors made through foils able to cover whole product range Springs offer mechanical function only ...

Page 47: ...eability Team By Nicola Padula and Nicola Bargagnati Components User Interface Mistral The User Interface is supplied from the IPC board through its auxiliary galvanically insulated output The ratings of this output are the following Platform Voutput Vdc Imax mA Mistral 15 0 5 600 ...

Page 48: ...cola Bargagnati Components Cooling Fan Induction Power Control IPC I270 Specification of fan voltage 12 V max current 0 5 A Power cons 6 W Nominal speed 2700 rpm 10 Nominal noise 49 dBA Brushless motor The Fan is driven with square wave in frequency and not in electric voltage The RPM value depend to the product state ...

Page 49: ...la Bargagnati Components Cooling Fan Induction Power Control IPC I200 Specification of fan voltage 12 V max current 0 9 A Power cons 14 4 W Nominal speed 2800 rpm 10 Nominal noise 54 dBA Brushless motor The Fan is drived with square wave in frequency and not in electric voltage The RPM value depend to the product state ...

Page 50: ...ning and Serviceability Team By Nicola Padula and Nicola Bargagnati Housing I270 Coils I270 Touch control I270 Cable IPC UI I270 Fan I270 Converter board I270 Repair Guide Line Housing I200 Coils I200 Touch control I200 Cable IPC UI I200 Fan I200 Converter board I200 ...

Page 51: ...ing and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Housing disassembly Mistral I270 Remove 6 screws from the frame Turn the hob to have the glass on top side Open the hob only from top The back side of the frame is fixed with 2 hooks ...

Page 52: ...chnical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Housing disassembly Mistral I270 Open the hob only from top Turn the glass frame in the front upwards Push it backwards to unhook the clips at the back side ...

Page 53: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Coils disassembly Mistral I270 4 hooks ...

Page 54: ...IDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Coils disassembly Mistral I270 Rotate the left coils in left side and the right coils in the right side ...

Page 55: ...ATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Coils disassembly Mistral I270 Disconnect the coils pins Disconnect the NTC faston ...

Page 56: ...MEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Touch control disassembly Mistral I270 Unclip the touch control from the support pins and disconnect the wiring to the IPCs ...

Page 57: ...ORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Cable IPC UI disassembly Mistral I270 Unplug the 2 connectors IPC side UI side ...

Page 58: ...N CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Fan disassembly Mistral I270 Remove the 2 fixing screws Unplug the cable from the IPC board ...

Page 59: ...ONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Converter board disassembly Mistral I270 Disconnect the cable for IPC Remove the 4 fixing screws ...

Page 60: ...ing and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Housing disassembly Mistral I200 Remove 6 screws from the frame Turn the hob to have the glass on top side Open the hob only from top The back side of the frame is fixed with 2 hooks ...

Page 61: ...chnical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Housing disassembly Mistral I200 Open the hob only from top Turn the glass frame in the front upwards Push it backwards to unhook the clips at the back side ...

Page 62: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Coils disassembly Mistral I200 Remove the 4 screws ...

Page 63: ...IDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Coils disassembly Mistral I200 Rotate the left coils in left side and the right coils in the right side ...

Page 64: ...ATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Coils disassembly Mistral I200 Disconnect the coils pins Disconnect the NTC faston ...

Page 65: ...MEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Touch control disassembly Mistral I200 Unclip the touch control from the support pins and disconnect the wiring to the IPCs ...

Page 66: ...RPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Cable IPC UI disassembly Mistral I200 Unplug the 2 faston IPC side UI side ...

Page 67: ...N CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Fan disassembly Mistral I200 Remove the 3 fixing screws Unplug the cable from the IPC board ...

Page 68: ...MEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Repair guide line Converter board disassembly Mistral I200 Disconnect the cable for IPC Remove the 2 fixing screws Disconnet the power cable ...

Page 69: ...TION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Demo Mode Configuration Mode Power Managment Failure code I200 and I270 Wiring Diagram Troubleshooting ...

Page 70: ...I270 Follow same procedure after unplugged the hob to deactivate the Demo Mode To access the demo mode press and hold for 5 seconds the Booster P of the second zone within 60 seconds the hob is plugged in and after the config code is shown Once the demo mode is active the letters dE d on the left side and e on the richt side will appear and the mode is active I270 I200 ...

Page 71: ...eability Team By Nicola Padula and Nicola Bargagnati Operation Configuration Mode Mistral I200 and I270 Within the first minute after the hob is plugged in execute the following key combo on the right timer indicated in the picture below Press consequently button and then CL button ...

Page 72: ...s ready to accept the configuration number For example if the conf code is 01 press button of the righter timer to increase the number from 0 to 1 then press CL to confirm PS the conf codes range is from 00 to 09 10 conf sets up always 0 on the left side at this time Set configuration code Press CL button The default configuration will appear is 00 O C 1 0 Example shown for I200 Example shown for ...

Page 73: ...thin 60 seconds after the hob is plugged in To access the power management it needs to be pressed and hold for 5 seconds the button of timer the one on the right side if 2 timers are available after the config code is shown The display will show PL Once the power limitation menu is active press again CL to access the settings Through the and button of right timer is possible to scroll settings To ...

Page 74: ...he mains voltage check if it is inside nominal range plus minus tolerance min 180V max 265V 2 If mains line voltage is OK then replace the IPC IPC 6 Main Frequency Wrong Zero Crossing Fault 1 Check the frequency of the phase connected to the IPC If the frequency is not 50 2 Hz then the cause of the failure is not due to the appliance 2 If frequency is OK then replace the IPC BURNER 12 Under Curren...

Page 75: ...4 Heatsink NTC shorted 1 Change the IPC IPC 35 Heatsink NTC open 1 Change the IPC BURNER 36 Coil1 2 NTC shorted 1 Check if the NTC coil that is showing the failure is well plugged in the proper connector 2 Replace the interested Coil with a new one 3 If replacing the Coil with a new one did not fix the appliance then the old coil is still good Put it back in the appliance Change the IPC BURNER 37 ...

Page 76: ... IPC 47 IPC WIDE communication error Time Out UI TSM 1 Verify connection of the product to the main 2 Verify connection between User Interface and IPC 3 Change the User Interface 4 Change the IPC UI WIDE communication error IPC WIDE communication error live tag IPC WIDE communication error CRC Error UI 56 Configuration error in EEPROM 1 1 Change the HMI COOKTOP 58 EEPROM Configuration Error 1 Veri...

Page 77: ...bleshooting Component Fault Description Service Action UI 60 CRC error in EEPROM 1 2 Change the HMI IPC 61 60730 Micro Register Error 1 Switch off and on the cooktop 2 Replace the IPC 60730 Micro RAM Error 60730 Micro FLASH Error CH1 CH2 Io Port Error 60730 Micro Program Flow Error 60730 Micro Watchdog Error BURNER 76 Coil 1 2 NTC Stuck 1 Change the coil tray 2 Change the IPC ...

Page 78: ...or some minutes if the warning message does not disappear execute the following action 1 Check the Cooktop installation 2 Check if the customer is using wrong diameter size pan pot 3 Change the IPC BURNER 82 Coil 1 2 Over Temperature Warning message Do not use the affected cooking zone for some minutes if the warning message does not disappear execute the following action 1 Check the Cooktop insta...

Page 79: ...il under current Type 1 1 Check if the coil that is showing the failure is well plugged in the proper connector 2 Replace the coil with a new one coil of the same size If this does not fix the hob then the old coil is still good place it back in the appliance 3 Change the IPC to which the coil is connected F 21 main frequency wrong Type 2 1 Check the frequency of the phase connected to the IPC If ...

Page 80: ...en circuited Type 1 1 Check if the coil NTC that is showing the failure is well plugged in the proper connector 2 Replace this coil with a new one NTC temp value is out of the spec range 3 If replacing the coil with a new one did not fix the appliance then the old coil is still good Put it back in the appliance Change the IPC showing the failure F 40 IPC failure Type 1 2 1 Replace the related IPC ...

Page 81: ...eck the wire between USIF and IPC 3 Replace the related IPC F 47 One IPC only is not responding within a time when it is polled Type 2 1 Check if the harness wires WIDE cables are well connected in the related connectors If this does not fix the appliance then 2 Replace the related IPC F 47 WIDE communication error Type 3 1 Check if the harness wires WIDE cables are well connected in the related c...

Page 82: ...1 Configure the related IPC If this does not fix the appliance then 2 Replace the related IPC with a new one 3 NTC for double zone has to be connected in the front connector not in the rear F 60 USIF I O Button error Type 3 1 Replace the USIF F 60 There is an access E2PROM memory error The memory is damaged Type 3 1 Replace the USIF F 63 Not correct communication USIF IPC Type 2 1 Verify connectio...

Page 83: ... Troubleshooting C 81 NTCs Board or Heatsink Type 2 1 Check the cooktop installation and cool down the appliance over temperature C 82 Coil Over Temperature Type 1 1 Check the cooktop installation and cool down the appliance Code shown on display Failure description Type of failure Points to check subsequently until the appliance starts to work properly again ...

Page 84: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Trouble Shooting Wiring Diagram Mistral I270 example ...

Page 85: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Trouble Shooting Wiring Diagram Mistral I200 example ...

Page 86: ... CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Product Architecture Mistral I 200 and I270 Legenda Safety Points Marketing information ...

Page 87: ...HIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Marketing Mistral I 200 Product Architecture Round Coils Oviform Coils ...

Page 88: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Marketing Mistral I 270 Product Architecture ...

Page 89: ...WHIRLPOOL CORPORATION CONFIDENTIAL EMEA CS Quality Technical Training and Serviceability Team By Nicola Padula and Nicola Bargagnati Marketing Legenda TBC To Be Confirmed ...

Page 90: ...push on a specific knob the hob is blocked 1 RESIDUAL HEAT INDICATOR a H is appearing as long as the T C is above 60 C 2 PAN DETECTION the display flashes when there is no pan on the burner 3 ANTI SPILLAGE SYSTEM cuts the power off in case of spillage on the control area 4 OVERHEATING LOCK When the T C is too high 5 VENTILATION The hob protects the furniture by ventilated system 6 AUTO OFF SYSTEM ...

Reviews: