WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati
F-36
Coil #
– temperature sensor
short-circuited
Type 1
1)
Check if the coil NTC, that is showing the failure, is well plugged in the proper
connector.
2)
Replace this coil with a new one.
NTC temp value is out of the
spec range.
3)
If replacing the coil with a new one did not fix the appliance, then the old coil is still
good. Put it back in the appliance. Change the IPC showing the failure
F-37
Coil #
– temperature sensor
open-circuited
Type 1
1)
Check if the coil NTC, that is showing the failure, is well plugged in the proper
connector.
2)
Replace this coil with a new one.
NTC temp value is out of the
spec range.
3)
If replacing the coil with a new one did not fix the appliance, then the old coil is still
good. Put it back in the appliance. Change the IPC showing the failure
F-40
IPC failure
Type 1,2 1)
Replace the related IPC
F-41
Touch malfunction
Type 3
1)
Replace USIF
F-42
DC link over voltage
Type 2
1)
Measure the mains voltage, if it is correct then:
2)
Replace the related IPC
Code shown
on display
Failure description
Type of
failure
Points to check subsequently until the appliance starts to work properly again.
Troubleshooting
Failure description / repair Mistral I270