background image

Summary of Contents for UXT2030AAW

Page 1: ...uently Grease shoutd not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element WARNING _ _ TO REDUCE THE RISK OFINURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray turn off the burner BE CAREFUL TO PREVENT BURNS if the flames ...

Page 2: ...exist remove the hood damper flap Sometimes when using a wall cap it is easier to duct vertically and then use an elbow as shown FIG B WALL CAP 1 1 4 x 10 DUCT _ ROOF CAP __ DAMPER FIG C Straight up through the roof us ing 7 round duct for single story instal lations UXT2030AA and UTX2036AA only WALL CAP ROOF CAP FIG D Ducting straight up through the roof using 3 x 10 rectangular duct For single s...

Page 3: ...t knockout back with pliers FIG 3 PREPARE THE INSTALLATION LOCATION Omit STEP 1 if hood will be installed under cabinets with flush bottom 1 For installation on recessed bottom cabinets only Attach a wood filler strip at each side of recessed are under cabinet Use two 1 x 2 strips cut to length If recess is deeper than 1 use thicker strips Attach strips with 1 1 4 wood screws 3 from end end of str...

Page 4: ...rd Use only metal ductwork DO NOT USE PLASTIC DUCT Assemble duct run securely so that in case of a grease fire on the range the fire will be contained inside metal ductwork Tape all duct connections 2 Follow appropriate directions below for type of duct run you install a Wall Cap Discharge FIG 7 Use saber saw or keyhole saw to to cut hole slightly larger than duct size used so that duct will line ...

Page 5: ...ed hole with green ground screw provided FIG 11 I 7 Replace wiring box cover and screw Make sure that all wiring is safely contained inside 8 Install light 75 Watt maximum For easier installation squeeze plastic lens and remove it from hood Remember to reinstall lens FIG 12 LIGHT LENS 3 Adjust hood so that hood front is flush with cabinet frame 4 Tighten hood mounting screws firmly 5 Fasten wiring...

Page 6: ...FIG 13 The ductfree filter is not washable and will last up to twelve months with normal use Replace the filter when colored side becomes noticeably dirty or discolored When installing filter make sure that filter slides under retaining tabs on back of fan housing MAKE SURE THAT COLORED SIDE OF FILTER IS NEXT TO FAN WHEN FILTER IS INSTALLED Turn filter retainer so that arrows on retainer point tow...

Page 7: ...1066 47001081 47001067 47001082 47001068 71001171 UXT2030AA UXT2036AA Series 7 Round Ducted Hood Part Number 47001055 706189 47001056 47001057 47001080 47001059 03050041 47001060 47001088 47001062 47001063 m m m 47001065 47001083 47001066 47001081 47001067 47001082 47001068 71001171 Description Outlet Box Cover 8 18 x 3 8 Phillips Truss Sheet Metal Screws Bulb Holder with Wires Light Lens Screw Nu...

Page 8: ...ties are void if the original serial numbers have been removed altered or cannot be readily determined 3 Light bulbs water filters and air filters 4 Products purchased for commercial or industrial use 5 The cost of service or service call to a Correct installation errors For products requiring ventilation rigid metal ducting must be used b Instruct the user on the proper use of the product c Trans...

Reviews: