9
Install Range Hood
1.
Using 2 or more people, hang range hood on 2 mounting
hooks through the rectangular cutouts on back of hood.
2.
Level the hood with leveling screws in mounting hooks or
rectangular cutouts, using a level across bottom of hood.
3.
Secure hood with 4 screws through remaining 4 holes in
hood.
4.
Install transition with 2 screws.
Connect Vent System
(for vented installations only)
1.
Fit vent system over transition piece.
2.
Seal connection with clamps.
Make Electrical Connection
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install the
UL-listed or CSA approved
¹⁄₂
" strain relief.
4.
Run 3 wires, black, white and green (14AWG) in
¹⁄₂
" conduit
from service panel to terminal box.
5.
Use UL listed wire connectors and connect black wires
together.
6.
Use UL listed wire connectors and connect white wires
together.
7.
Connect ground wire to green and yellow ground wire in
terminal box using UL listed wire connectors.
A. Mounting hooks
B. Mounting screws
C. Leveling screws
D. Centerline on wall
E. Transition
F. 3.5 x 9.5 mm screws
G. Terminal box
A. Vent system
B. Transition piece
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
B
C
D
E
B
F
F
G
A
B
A. UL-listed or CSA
approved strain relief
B.
¹⁄₂
" conduit
C. Terminal box
D. Black wires
E. Green (or bare) wire connected
to yellow-green wire
F. White wires
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
D
C
B
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
Summary of Contents for W10029770A