COMPONENT ACCESS (Cont.)
Whirlpool
®
24" Compact Condensing Dryer
n
4-15
11.
Remove the twelve (12) T20 screws from the condenser
cover (see Figure 3).
Figure 3
12.
Remove harness from clip (see Figure 4).
Figure 4
13.
Remove christmas tree clip using pliers (see Figure 4).
14.
Remove the condenser cover by lifting up and pulling away
from front panel.
Figure 5
15.
Remove motor by lifting it straight up and away from base
(see Figure 5).
Figure 5
Removing the Water Level
Sensor, Drain Pump, and
Front NTC
To Remove the Water Level Sensor
1.
Unplug dryer or disconnect power.
2.
Perform the procedure on
, “Removing the Top
Panel” prior to performing the following steps.
3.
Perform the procedure on
, “Removing the Side
Panels” prior to performing the following steps - only
necessary to remove the left side panel to access these
components).
4.
Clip the wire tie securing the pipe and disengage pipes from
back of unit by pulling them up (see Figure 1).
Figure 1
5.
Remove T20 screw from rear access panel (see Figure 2).
Figure 2
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.