For Service Technician Use Only
COMPONENT TESTING
(
Cont.
)
3-4
n
Whirlpool
®
24" Compact Condensing Dryer
Main Control (ACU) Connectors and Pinouts
Figure 1 - Main Control (ACU)
CN05
CN10 CN15 CN14 (OPEN)
CN11
CN 05 - Motor Power
CN05-1 Open
CN05-2 Open
CN05-3 Open
CN05-4 RD/R Drum Motor L1
CN05-5 RD/R Drum Motor N
CN08
(OPEN)
CN13
CN04 CN03
CN01
CN02
CN09
CN17
CN18 (OPEN)
CN07
OPEN
CN12
(Open)
1
3
CN10
CN15
5
6
3
4
1
2
CN14
6
7
4
5
2
1
3
CN14-1 Open
CN14-2 Open
CN14-3 R/ROJ 5V DV
CN14-4 R/ROJ GND
CN14-5 R/ROJ Water Sensor
CN14-6 Open
CN14-7 Open
CN 10 - Door Switch
CN10-1 R/ROJ 12 VDC
CN10-3 R/ROJ Return
CN 15 - Thermistors and Reed Switch
CN15-1 BK/N Front Thermistor
CN15-2 BK/N Front Thermistor
CN15-3 BU/AZ Reed Switch
CN15-4 BU/AZ Reed Switch
CN15-5 R/ROJ Inlet Thermistor
CN15-6 R/ROJ Inlet Thermistor
CN 14 - Water Level Sensor
CN11
2
CN 11 & CN 08 - Not Used
CN11-1 CN18-1 Open GND
CN11-2 CN18-1 Open WIN Communication
CN11-3 CN18-1 Open 5 VDC
CN11-4 CN18-1 Open 12 VDC
1
3
4
CN08
2
1
3
4
CN13
2
1
3
4
CN09
1
2
CN17
2
1
CN 13 - Motor Communication
CN13-1 BU/BU GND
CN13-2 BU/BU WIN Communication
CN13-3 BU/BU 5 VDC
CN13-4 BU/BU 12 VDC
CN 09 - Drain Pump
CN09-1 RD/R Drain Pump
CN09-2 RD/R 5 VDC Neutral
3
4
5
11
CN03
1
2
CN 17 - HMI
CN17-1 RD/R 12 VDC
CN17-2 RD/R 5 VDC
CN17-3 RD/R WIN Communication
CN17-4 RD/R GND
CN17-5 RD/R Wake Up
CN 01 & CN 02 Moisture Strips and Ground
CN01-1 BK/N Moisture Strips
CN02-1 GR/YL / VE/JA Ground
CN 03 - L1 & L2
CN03-1 BR/MAR L1
CN03-2 BR/MAR L2
CN04
1
2
3
4
CN 04 - Heater
CN04-1 BR/MAR Heater_1
CN04-2 BU/BL Line_HMR
CN04-3 Open
CN04-4 BR/MAR Heater_2
CN05
1
2
3
4
5